Instructions & Assembly
Congratulations Congratulations on your new MEDQUIP for many occasions.
Table of Contents Congratulations ........................................................................................................................ Indication for Use ..................................................................................................................... Important Safeguards .............................................................................................................. ● DANGER ...............................................................................
● Tubing Cleaning Instructions ........................................................................................................................ Breastmilk Storage Guidelines ........................................................................................................ ● Important Notes .......................................................................................................................... Tips ...............................................................................
Important Safeguards The MEDQUIP Breast Pump is designed for a single user and should never be shared or resold; doing so will void the warranty. READ ALL INSTRUCTIONS BEFORE USING DANGER: To reduce the risk of electrocution: ● Always unplug this product immediately after using. ● Do not use while bathing. ● Do not place or store this product where it can fall or be pulled into a tub or sink. ● Do not place or drop into water or other liquid.
Important Safeguards (Continued) ● Make sure the voltage of the AC/DC Adapter is compatible with the power source. ● Plug the AC/DC Adapter into the electrical outlet first, then plug the Power Cord into your MEDQUIP Breast Pump. ● MEDQUIPhas provided an AC/DC Adapter and/or Li-Ion battery pack with this device. Using any other AC/DC Adapter or Li-Ion battery pack not approved by the manufacturer voids the warranty.
Parts Guide AC/DC Adapter Vacuum Tubing with Adapter Breast Pump Main Unit Bottle Adapter Kit (2 Sets) Manual Diaphragm Add-On Kit English 5 Expression Collection Combo Kit (2 Sets)
Parts Guide ● Electric Pump Main Unit TOP VIEW BOTTOM VIEW LCD Screen Vacuum Adjusting Wheel Expression Button M Button Power Button Battery Cover Tubing Adapter Inlet AC/DC Adapter Inlet ● LCD Screen Guide Suction Level indicator Power indicator Swift Expression indicator Natural Expression indicator M Button Icon AM PM Alarm indicator Time indicator English 6
Parts Guide ● Expression Collection Combo Kit Cap Diaphragm Electric-pump Diaphragm Kit Cup with O-Ring Silicone Cushion Breastshield Body One-Way Valve Bottle Adapter Collection Bottle Bottle Base English 7 Expression Collection Kit
How to Assemble the Expression Collection Kit Your MEDQUIP Breast Pump comes pre-assembled; however, you will need to re-assemble it after each cleaning. (For cleaning instructions, see page 29) Below is a step-by-step guide for assembling the Expression Collection Kit: 1. Hold the "horn" of the Breastshield Body in one hand. Make sure the bottle-thread side opening is facing up. 2.
How to Assemble the Expression Collection Kit (Continued) 3. With your thumb and forefinger, gently smooth closed any openings on the tip of the One-Way Valve and shape into a straight line. Note: This is critical to the performance of the Pump. 4. Carefully twist on the Bottle Adapter to the Breastshield Body for a secure fit. Note: Be sure not to bump the One-Way Valve when twisting the Breastshield Body & the Bottle Adapter pieces together. If you bump the One-Way Valve, repeat step 3.
How to Assemble the Expression Collection Kit (Continued) 5. With the Bottle Adapter in one hand, twist on the Collection Bottle for a secure fit.
How to Assemble Electric-pump Diaphragm Kit 1. With the Cup in one hand, place the Silicone Diaphragm in the Cup (matching the shape of the Cup). Press around the edges of the Diaphragm for a secure fit. Make sure the Diaphragm is evenly mounted on the Cup and there is no gap in between them. 2. Place the Cap on the Cup & Diaphragm. (Be sure to align the hinge and hinge cover.) Press tightly to seal.
How to Assemble Expression Collection Combo Kit 1. With the O-Ring side down, put the Electric Pump Diaphragm Kit into the top of the Breastshield Body opening. Twist the Electric-Pump Diaphragm Kit clockwise into the Breastshield Body until it locks into place. Turn Clockwise 2. With the Breastshield Body in one hand, place the Silicone Cushion in the Breastshield Body (matching the shape of the horn). Secure the lip of the Cushion around the edges of the horn.
How to Assemble Expression Collection Combo Kit (Continued) 3. Take the open-end of Vacuum Tube (the end without the adapter) and connect to the Tubing Connector located on the Cap. Push together firmly for a tight seal. Note: Make sure there is no moisture in the tubing. *To Use As a Single Pump: Remove one tube and close the T-connector. T-connector Tubing Connector 4. Make sure the Tubing Connector is properly inserted into the Tubing Adapter Inlet on the Electric Pump Main Unit.
Power Options Your Electric Breast Pump may be operated under any of the following power supply modes: Using your AC/DC Adapter (included): ● Electrical safety can only be achieved when using the AC/DC Adapter which was provided with the Pump. Use of any another Adapters causes concern for the safety of the product and/or the user and voids the warranty. 1. Plug the AC/DC Adapter into an electrical outlet. 2. Attach the Power Cord to the AC/DC Adapter Inlet on the Electric Pump Main Unit.
Power Options (Continued) Using 4 AA Alkaline batteries : AA Battery Compartment 4 AA Batteries (not included) ● Always replace all 4 AA Batteries at the same time. Breast Pump is not going to be ● Remove all batteries from the Electric Pump Base if the MEDQUIP used for extended periods of time. ● Properly dispose of all batteries, according to regulations for environmental protection and recycling. Note: Alkaline Batteries may present a risk of fire or chemical burn if mistreated.
Install the Batteries: AA Alkaline 1. Open the Battery Cover. 2. Remove the old batteries if you are replacing them.
Install the Batteries:AA Alkaline (Continued) 3. Insert 4 new AA Alkaline Batteries. Do not mix old and new batteries. Note: Make sure the polarity is correct as indicated. 4. Close the Battery Cover, making sure it "snaps" into place.
Pumping Instructions 1. Hold the Expression Collection Combo Kits to your breasts so that your nipples are centered inside the Breastshield. Note: Please check for correct fitting of the shield. 2. Press the Power Button to begin pumping.
Pumping Instructions (Continued) 3. The LCD Screen shows the time of your last pumping session for a few seconds. The Pump will automatically start from the Reflex Expression for 15 seconds then switch to the Swift Expression automatically. 4. Adjust the suction in the Swift Expression to your comfort level while pumping by rolling the Vacuum Adjusting Wheel up (+) or down (-).
Pumping Instructions (Continued) 5. Depending on your preference, and your baby's sucking habit, you can choose to express your milk in either the Swift Expression or Natural Expression settings. To switch from Swift Expression to Natural Expression, press the Expression Button once. Expression Button 6. To check which expression setting that you are on, check the LCD display for the Expression Cycle Icon. The breast shape icon indicates that you are at Reflex / Swift Expression setting.
Pumping Instructions (Continued) 7. Adjust the suction in the Natural Expression to the most comfortable and effective level while pumping by rolling the Vacuum Adjusting Wheel up (+) or down (-) . Vacuum Adjusting Wheel 8. When your pumping session is finished, turn the Pump off by pressing the Power Button.
Pumping Instructions (Continued) 9. After the Pump has been turned off, the LCD Screen will remain on for a few seconds. The display will show the total amount of pumping time, then automatically switch to Standby/Clock mode, or Alarm Clock Mode if the Alarm was turned on. Note: Make sure there is no suction on the nipples before removing the Breastshield.
Suction Level Whenever you select a Suction Level (in any Expression setting), your MEDQUIP Breast Pump remembers it until you change it. This feature becomes useful after you are familiar with this pump. Your MEDQUIP Breast Pump retains the memory of your previous pumping level without you having to reset your preferred level each time you pump. To set your preferred Suction Level: 1.
M Button (My Favorite Pattern) One of the great features of your MEDQUIP Breast Pump is the M Button (My Favorite Pattern). You can easily set and recall your personal Expression pattern by pressing the M Button. It is extremely helpful if you usually use Natural Expression setting to express your milk. You do not need to use the M Button if you usually use Swift Expression for your expression. To set My Favorite Pattern: 1.
Setting the Time How to Adjust the Clock: 1. While in the Clock/Standby Mode, press and hold the M Button for 3 seconds to go into Clock Setting mode. A beep will sound and the AM/PM icon will flash. 2. To change between AM/PM, use the Vacuum Adjustment Wheel 3. Press the Expression Button 4. To change the Hour, use the Vacuum Adjusting Wheel 5. Press the Expression Button up (+) or down (-). once to change from AM/PM to the Hour. The Hour number will flash. to increase (+) or decrease (-) the hour.
Setting the Time (Continued) Press M Button for more than 3 sec AM Press the Expression Button Clock ** Roll Adjusting Wheel to adjust.
Alarm Clock Mode It is advised to pump regularly in order to maintain a good milk supply from your body. The Alarm Clock Mode is designed to remind you when it's time for your next pumping cycle. By keeping a regular expression pattern, your body maintains a good milk supply. After setting the time interval between each pumping session, the Alarm countdown will automatically start after the previous pumping cycle has stopped. An alarm will sound when the pre-set time has passed. How to Adjust the Alarm: 1.
Alarm Clock Mode (Continued) Press the M Button AM Press the Expression Button Clock ** Roll Adjusting Wheel to adjust.
Cleaning Instructions Unless otherwise instructed by your healthcare provider, follow these sanitizing and cleaning instructions. Sanitize Prior to First Use: Before you use your MEDQUIP Breast Pump for the first time, disassemble and boil all parts of the Expression Collection Combo Kit and the Manual Diaphragm Add-on Kit in water for 10 minutes. ● Be sure to use enough water to keep all parts afloat while boiling. ● Do NOT boil Tubing or Tubing Adapter.
Cleaning Instructions (Continued) ● Do NOT use solvents or abrasives. ● Rinse with hot, clean water. ● To clean the Electric Pump Main Unit, wipe it with a wet wipe or damp cloth, using only water or water mixed with a mild soap. Tubing Cleaning Instructions: ● Wipe the outside of the Tubing with a clean, damp cloth. Avoid getting water or other fluids inside the Tubing. ● If liquids are found inside Tubing, rinse the Tubing with clean hot water. Hang to AIR DRY COMPLETELY BEFORE USING.
Breastmilk Storage Guidelines Check with your healthcare provider or an International Board Certified Lactation Consultant for specific storage instructions. This information is based on current research and applies to mothers who have healthy, full-term babies who are storing their milk for home use. Important Notes: ● STORAGE CONTAINERS: The best option for storing human milk is glass or hard-sided plastic containers with well-fitting tops.
Breastmilk Storage Guidelines (Continued) Place Refrigerator Temperature How long Things to know 39°F or colder ● Up to 72 hours is best. ● Up to 5-8 days is okay for very clean expressed milk. Store milk in the back of the main body of the refrigerator. 0°F or colder ● Up to 6 months is best. ● Up to 12 months is okay. Store milk toward the back of the freezer where temperature is most constant.
Tips Pumping Tips: The most important and successful part of pumping is the let-down reflex. The let-down reflex is when your milk begins to flow freely. ● Try relaxing with a warm, wet compress on your breasts. ● Drink plenty of fluids. ● Avoid outside distractions. ● Visualize yourself happy, well rested and successful at pumping. ● Sometimes a light circular massaging of the breasts prior to and/or during a pumping session will help your let-down reflex start/continue.
Tips (Continued) Battery Storage: ● When storing the battery for a short period of time, store within the following temperature range: -4°F to 140°F (-20°C to 60°C). ● When storing the battery for an extended period of time, store within the following temperature range: 32°F to 77°F (0°C to 25°C).
Troubleshooting Interruption of Electrical Service: If you experience an interruption of electrical service, due to a power surge or other factors, during normal operation of Breast Pump, try the following: your MEDQUIP ● Unplug the AC/DC Adapter cord from the electrical outlet and wait for five seconds. ● Plug the AC/DC Adapter cord back into the electrical outlet. ● If problem persists, try a different electrical outlet.
Troubleshooting (Continued) No response while operate Adjusting Wheel and Mode button: You CANNOT adjust the suction level or switch between Swift Expression and Natural Expression while in My Favorite Pattern. If you have to, stop My Favorite Pattern by pressing the M Button.
Technical Data Power Requirements: ● AC/DC Adapter (included) North American Plug configuration: Brand: Acute Ideas Model:MLF-012W1201000, 100V ~ 240V AC, 50/60 Hz, 0.4A, wall plug type AC/DC Adapter with DC 12V/1A output. ● Batteries: 4 AA batteries; 1.5V Alkaline Technical Specifications: VACUUM: Reflex / Swift Expression:-85~-185mmHg(-11.3~-24.6kpa) Natural Expression:-110~-250mmHg(-14.6~-33.
Manual Breast Pump - Quick Reference Guide Parts Guide: ● Manual Diaphragm Add-On ● Expression Collection Combo Kit Adjusting Valve * Adjusting Valve Stem Manual Diaphragm Handle ** Valve Stem * Handle Manual Diaphragm *** Manual-pump Diaphragm Kit Cup with O-Ring Breastshield Body Silicone Cushion Note: 1. The parts in " * " marks are specific to the Manual Breast Pump. 2.
Manual Breast Pump - Quick Reference Guide (Continued) How to Assemble the Expression Collection Combo Kit: Your MEDQUIP Manual Breast Pump comes pre-assembled; however, you will need to re-assemble it after each cleaning. (For cleaning instructions, see Instruction and Assembly manual.) Below is a step-by-step guide for assembling the Expression Collection Combo Kit: 1. Hold the "horn" of the Breastshield Body in one hand. Make sure the bottle-thread side opening is facing up.
Manual Breast Pump - Quick Reference Guide (Continued) 3. With your thumb and forefinger, gently smooth closed any openings on the tip of the One-Way Valve and shape into a straight line. Note: This is critical to the optimal performance of the Pump. 4. Carefully twist on the Bottle Adapter to the Breastshield Body for a secure fit. Note: Be sure not to bump the One-Way Valve when twisting the Breastshield Body & the Adapter pieces together. If you bump the One-Way Valve, repeat step 3. 5.
Manual Breast Pump - Quick Reference Guide (Continued) How to Assemble the Manual-Pump Diaphragm Kit: 1. With the Cup in one hand, place the Manual Silicone Diaphragm in the Cup (matching the shape of the Cup). Press around the edges of the Diaphragm for a secure fit. Make sure the Diaphragm is evenly mounted on the Cup and there is no gap in between them. Turn Clockwise 2. Twist the Manual-pump Diaphragm Kit clockwise into the Breastshield Body until it locks into place.
Manual Breast Pump - Quick Reference Guide (Continued) "U" shape slot Swift Natural Hinge 3. Place the "U" shape slot of the Handle onto the recess of the Adjusting Valve Stem. (There are 2 recesses on the Adjusting Valve Stem. The upper recess replicates the Swift Expression setting, and the bottom recess replicates the Natural Expression setting of MEDQUIPElectric Pump.) 4. Push the Handle down onto the hinge of the Cup until it "snaps" into place. 5.
Manual Breast Pump - Quick Reference Guide (Continued) Using the Manual Pump: Note: There are two recesses for attaching the handle to the Manual Pump. You can toggle between these two settings by pushing the Adjusting Valve Stem away from the “U” shape tip of the Handle to dislocate the connection. Reattach the tip of the Handle using a different recess on the Adjusting Valve Stem. Swift Expression Setting: This setting is for a fast, shallow suction.
Manual Breast Pump - Quick Reference Guide (Continued) Troubleshooting: ● Insufficient Vacuum ● Center your nipple in the Breastshield. Ensure a complete seal of the Breastshield, making sure there are no gaps between the breast and the Breastshield. gap ● Verify that the Handle is "snapped" into place against the Valve Stem. ● Check the suction level by turning the the Adjusting Valve.
Warranty Limited Consumer Product Warranty (United States) This MEDQUIP Electric Breast Pump is warranted to the original consumer "the purchaser" to be free from defects in material and workmanship which are not commercially acceptable for the period of one year from the date of purchase on the pump mechanism and a period of 120 days on all other components. Warranty coverage terminates if you sell or otherwise transfer this product to another person.
Warranty (Continued) If you wish to make a claim under this warranty, you will need the following: ● The entire original MEDQUIP product ● The original receipt showing date of purchase ● Return Authorization Number (RA#) ● Detailed description of the problem You, the purchaser, are responsible for all shipping charges. Do NOT send product without a RA#. To obtain a RA# and shipping address: Please contact MEDQUIP Customer Service Department by; Toll-Free: (888) 404-5666 Tel: (843)815-5301 Web: www.medquip.
P.O.