- Product specifications
- Alarm and alert escalation
- Altitude range
- Audio frequency
- Backlight
- Basal delivery
- BG Target
- BG meter value
- Bolus delivery
- Bolus Wizard feature default settings
- Bolus Wizard feature specifications
- Carb ratios
- Delivery accuracy
- Easy Bolus feature
- Environmental conditions
- Essential performance
- Filling the infusion set and cannula
- Infusion pressure
- Insulin delivery default settings
- Bolus settings
- Basal settings
- Insulin sensitivity factor
- Low Reservoir reminder
- Max Bolus
- Normal bolus
- Occlusion detection
- Percent temp basal
- Program safety checks
- Pump dimensions
- Pump memory
- Pump weight
- Sensor default settings
- Wireless communication
- FCC notice
- IEC60601-1-2:4th Edition notice
- Guidance and manufacturer's declaration
- Icon glossary
- Product specifications
- 670G Performance Data and Technical Information
The following table lists the compatible infusion sets. The MMT numbers may
change if other compatible infusion sets become available.
Type MMT number
MiniMed Quick-set infusion set MMT-386, MMT-387, MMT-394, MMT-396,
MMT-397, MMT-398, MMT-399
MiniMed Silhouette infusion set MMT-368, MMT-377, MMT-378, MMT-381,
MMT-382, MMT-383, MMT-384
MiniMed Sure-T infusion set MMT-862, MMT-864, MMT-866, MMT-874,
MMT-876, MMT-884, MMT-886
MiniMed Mio infusion set MMT-921, MMT-923, MMT-925, MMT-941,
MMT-943, MMT-945, MMT-961, MMT-963,
MMT-965, MMT-975
MiniMed Mio Advance infusion set MMT-211, MMT-212, MMT-213, MMT-231,
MMT-232, MMT-233, MMT-242, MMT-243,
MMT-244
Additional MiniMed 770G System devices
• Accu-Chek Guide Link meter–the MiniMed 770G System is compatible with
an Accu-Chek Guide Link meter. The meter pairs with your pump, allowing
you to send BG meter readings to your pump.
• Guardian Link (3) transmitter (MMT-7911)–pairs with your pump for CGM. A
device that connects to a glucose sensor. The transmitter collects data
measured by the sensor and wirelessly sends this data to monitoring devices.
• Guardian Sensor (3) (MMT-7020)–used with your pump for CGM. The sensor
is a small part of the CGM system that you insert just below your skin to
measure glucose levels in your interstitial fluid. The sensor is a disposable,
single-use, device. Only use the Guardian Sensor (3) (MMT-7020) glucose
sensor with the transmitter. Do not use any other sensor. Other sensors are
not intended for use with the transmitter, and will damage the transmitter
and the sensor.
• MiniMed Mobile app (MMT-6101 for Android or MMT-6102 for iOS)–can be
downloaded onto multiple compatible mobile devices from the app store, but
the pump can be paired with only one compatible mobile device at any time.
■
Before you begin