User's Manual

Table 4. Using the docking station (continued)
Procedure: Do this:
To connect a printer USB cable to the docking station
(Figure 10):
Note: Compatible printer drivers are PCL3, PCL3e,
PCL4, PCL5C (color), PCL5e, PS2, PS2 (color), PS3.
Consult your printer manufacturer to determine the
correct page description language, eg, PS (PostScript) or
PCL (Printer Command Language).
1. Make sure the docking station is powered.
2. Correctly orient the printer USB cable plug in relation
to the USB port on the docking station.
3. Insert the plug into the port.
To connect an Ethernet cable to the docking station
(Figure 10):
Note: An Ethernet port may not be available on all
docking stations.
1. Make sure the docking station is powered.
2. Correctly orient the Ethernet cable plug in relation to
the Ethernet port of the docking station.
3. Insert the plug into the port until it snaps into place. A
flashing green LED in the Ethernet socket indicates a
10 Mbps connection, while a flashing yellow LED
indicates a 100 Mbps connection.
Note: The connection speed is dependent on the
external network hardware and wiring and is not user
configurable. The programmer will negotiate the fastest
connection available when connected to the Ethernet
network
To connect a VGA cable from an external monitor to the
docking station, in order to display the programmer
image on an external monitor (Figure 10):
Note: A VGA output connection may not be available on
all docking stations.
1. Make sure the docking station is powered.
2. Correctly orient the VGA cable plug in relation to the
VGA output connection of the docking station. The
pins of the VGA cable plug should align with the
holes of the VGA output connection.
3. Firmly insert the plug into the connection.
4. Secure the screws of the plug to the connection.
Note: VGA output settings and resolution are not user
configurable.
To store the telemetry head on the docking station, when
the telemetry head is not in use (Figure 11):
1. Remove the plug from the accessory connector on
the back of the telemetry head.
2. Orient the telemetry head at a 90° angle to the back
leg of the docking station.
3. Place the accessory connector on the back of the
telemetry head over the accessory connector on the
back leg of the docking station.
4. Rotate the telemetry head downward 90° until it locks
into place.