User's Manual

Medtrum Ltd
Cibase Waord, 42-44 Clarendon Road
Waord, WD17 1JJ, United Kingdom
Tel: +44 (0)19 2331 2391
Medtrum Technologies Inc.
7F, Building 8, No. 200, Niudun Road
Shanghai 201203, China
Tel: +86-21-50274781
Fax: +86-21-50274779
www.medtrum.com
This product complies with Direcve
93/42/EEC (MDD) and Direcve
1995/5/EC (R&TTE).
CAN ICES-3 (B)/NMB-3(B)
REF MD-LQ-002
Version:1.0
Publicaon date: 6 Jan, 2017
UG782002GB
348140
©2017, Medtrum Technologies Inc. All rights reserved.
Log in to your EasyView Web Portal account and start
uploading data. During the data uploading process,
the green data indicator light on the USB dongle will
keep flashing. Once the data uploading is completed,
all the three indicator lights (the white power indica-
tor light, the green data indicator light and the red
fault indicator light) will flash five mes. Aer that,
only the white power light remains on unl the USB
dongle is disconnected from the computer.
3. Manufacturer’s Declaraon
The USB dongle is intended for use in the electromag-
nec environment specified below. The customer or
the user of USB dongle should make sure that it is
used in such an environment.
3.1 Electromagnec Emissions
Emissions Test
Compliance
RF emissions
EN 60601-1-2:2007+AC:2010, IEC
60601-1-2:2007, CISPR
11:2009+A1:2010, and IEC
60601-1-2:2014
RF emissions
EN 60601-1-2:2007+AC:2010, IEC
60601-1-2:2007, CISPR
11:2009+A1:2010, and IEC
60601-1-2:2014
Group 1
Class B
Immunity Test
Compliance
Level
±2.0 kV, ±4.0 kV,
±6.0kV, ±8.0 kV
contact
discharge
±2.0 kV, ±4.0 kV,
±8.0 kV, ±15.0
kV air discharge
±2.0 kV, ±4.0 kV,
±6.0 kV, ±8.0 kV
contact (56% RH)
±2.0 kV, ±4.0 kV,
±8.0 kV, ±15.0 kV
air (56% RH)
10 V/m
3.2 Electromagnec Immunity
IEC 60601 Test
Level
Electrostac
discharge (ESD)
IEC 61000-4-2
RF electromag-
nec field
immunity test
IEC 61000-4-3
10 V/m
Power frequency
magnec fields
IEC 61000-4-8
30 A/m
30 A/m
Warning:
1. The USB dongle should be avoided to use in the
environments near high voltage, high-intensity
magnec field, where the intensity of EM DISTUR-
BANCES is high.
2. Portable RF Communicaons equipment should be
used no closer than 30 cm (12 inches) to any part of
the Medtrum products. Otherwise, degradaon of
the performance of this equipment could result.
3. Use of this equipment adjacent to or stacked with
other equipment should be avoided, because it could
result in improper operaon. If such use is necessary,
this equipment and the other equipment should be
observed to verify that they are operang normally.
5.Appendix II: Technical Informaon
5.1 USB dongle Specificaons
Model: MD-LQ-002
Size: 70mm x 52mm x 23.3mm
Weight: 23 g
Operang Temperature Range: +5°C ~+40°C
Operang Relave Humidity Range: 20%~90%RH
Operang Atmospheric Pressure: 700~1060 hPa
Storage Temperature Range: -10°C~+55°C
Storage Relave Humidity Range: 20%~90%RH
Storage Atmospheric Pressure: 700~1060 hPa
Baery: 5V/1A
Limited Warranty: 1 year
Reference
number
Symbol Symbol
Meaning Meaning
Lot number
Do NOT use if
package is
damaged
4.Appendix I: Symbols and Icons
4.1 Product Label Symbols
SN
Manufacturer
Use by:
(yyyy-mm-dd)
Follow
instrucons
for use
Cauon: See
Instrucons for
use
IC
Waste
Electrical and
Electronic
Equipment
Storage
temperature
CE mark
Device serial
number
Authorized
representave
in the European
Community
Signifies
compliance with
Industry Canada
EMC and Radio
communicaons
requirements
5
6
7
Radio
communicaon
USB Dongle