Full Product Manual
Table Of Contents
- Slide Number 1
- Slide Number 2
- Slide Number 3
- Slide Number 4
- Slide Number 5
- Slide Number 6
- Slide Number 7
- Slide Number 8
- Slide Number 9
- Slide Number 10
- Slide Number 11
- Slide Number 12
- Slide Number 13
- Slide Number 14
- Slide Number 15
- Slide Number 16
- Slide Number 17
- Slide Number 18
- Slide Number 19
- Slide Number 20
- Slide Number 21
- Slide Number 22
- Slide Number 23
- Slide Number 24
- Slide Number 25
- Slide Number 26
- Slide Number 27
- Slide Number 28
- Slide Number 29
- Slide Number 30
- Slide Number 31
- Slide Number 32
- Slide Number 33
- Slide Number 34
- Slide Number 35
- Slide Number 36
- Slide Number 37
- Slide Number 38
- Slide Number 39
- Slide Number 40
- Slide Number 41
- Slide Number 42
- Slide Number 43
- Slide Number 44
- Slide Number 45
- Slide Number 46
- Slide Number 47
- Slide Number 48
- Slide Number 49
- Slide Number 50
- Slide Number 51
- Slide Number 52
GENERAL
Although all gas connections on the grill are leak tested at
the factory prior to shipment, a complete gas leak test check
must be performed at the installation site due to possible
mishandling in shipment, or excessive pressure unknowingly
being applied to the unit. Periodically check the whole system
for leaks following the procedures listed below. If the smell of
gas is detected at anytime you should immediately check the
entire system for leaks.
BEFORE TESTING
Make sure that all packing material is removed from the grill
including tie-down straps.
DO NOT SMOKE WHILE LEAK TESTING.
NEVER PERFORM LEAK TEST WITH AN OPEN FLAME.
Make a soap solution of one part liquid detergent and one
part water. You will need a spray bottle, brush, or rag to
apply the solution to the fittings. For the initial leak test, make
sure the L.P. cylinder is 80% full.
TO TEST
1. Make sure the control valves are in the “ ○ ” position
and turn on the gas supply.
2. Check all connections from the L.P. gas regulator and
supply valve up to and including the connection to the
manifold pipe assembly (the pipe that goes to the
burners). Soap bubbles will appear where a leak is
present.
3. If a leak is present, immediately turn off the gas supply
and tighten the leaky fittings.
4. Turn the gas back on and recheck.
5. Should the gas continue to leak from any of the fittings,
turn off the gas supply and contact customer service at
1-855-634-2627, language spoken: English, French,
Spanish 8 a.m.-5 p.m., PST. Monday-Friday.
Leak Testing
ALWAYS CHECK FOR LEAKS AFTER EVERY L.P.
TANK CHANGE
Check all gas supply fittings for leaks before each use.
It is handy to keep a spray bottle of soapy water near
the shut-off valve of the gas supply line. Spray all the
fittings. Bubbles indicate leaks.
Your grill is ready to use!
9
GAS FLOW CHECK
Each grill burner is tested and adjusted at the factory prior to
shipment; however, variations in the local gas supply may
make it necessary to adjust the burners. The flames of the
burners should be visually checked.
Flames should be blue and stable with no yellow tips,
excessive noise or lifting. If any of these conditions exist,
check to see if the air shutter or burner ports are blocked by
dirt, debris, spider webs, etc. If you have any questions
regarding flame stability, please call customer service
1-855-634-2627, language spoken: English, French, Spanish
8 a.m.-5 p.m., PST. Monday-Friday.
Installer Final Check List
USER, PLEASE RETAIN THIS MANUAL FOR FUTURE
REFERENCE.
PROPANE CYLINDER CAUTIONS
a) Do Not store a spare LP-gas cylinder under or near
this appliance.
b) NEVER fill the cylinder beyond 80 percent full.
c) If the information in “a” and “b” is not followed
exactly, a fire or explosion causing death or serious
injury may occur.
Minimum clearance from sides and back of unit to
combustible construction, 36 in. / 92 cm from sides
and 36 in. / 92 cm from back
All internal packaging removed.
Knobs turn freely.
Burners are tight and sitting properly on orifices.
Pressure regulator connected and set. Gas
connections to grill using hose & regulator
assembly provided (pre-set for 11 in. water column).
Unit tested and free of leaks.
User informed of gas supply shut off valve location
Only those parts recommended by the manufacturer should
be used on the grill.
Substitution will void the warranty. Do not use the grill until all
connections have been checked and do not leak.