Operating Instructions and Installation Instructions

2.3 ELECTRIC CONNECTION
VERY IMPORTANT: The appliance must be always connected to the ground, according to actual regulations.
The electric connection, should be executed only by qualified personnel who are aware of installation
regulations in force.
Before the connection, check if the electric network is prepared for the required power (see the data plate, or table
of technical characteristics).
The appliance must always be grounded in accordance with the regulations in force
The earth connection conductor is green/ yellow
With plug in devices must connect the plug to a wall socket with earth contact
The supply cable must be positioned that no point can reach a temperature 50 ยบ C higher than ambient temperature.
Appliance are equipped with power cord and are designed to operate at a frequency of 50/60 Hz.
Verify the type of electric alimentation in the label placed on the back side of the appliance near the cable inlet, in
the data plate placed in the dish warmer door, in the package label or in the characteristics table of technical
characteristics.
According to the models, see table of technical characteristics, the alimentation could be, 230 V ~, single-phase
current (2+1 conductors) or 400V 2N ~, two-phase current (3+1 conductors), or three-phase current 400V 3N ~ (4+1
conductors).
To proceed this transformation see next schemes:
monophasic 220 - 240 V biphasic 380 - 415 V 2N triphasic 380 - 415 V 3N
2 + 1 conductors 3 + 1 conductors 4 + 1 conductors
and to substitute the alimentation cable for the adequate, monophasic type HO5VV-F and
triphasic type HO5RR-F.
NOTE: The producer is not responsible for eventual direct or indirect damages owing to a wrong installation,
regulations misunderstanding or standards in force not respected.
INSTRUCTIONS MANUAL
9
1 2 3 54
L N
1 2 3 54
L1 NL2
1 2 3 54
L1 NL3L2