Built-in measurements
The dimensions of the opening to be made on the cabinet for fitting the oven are
indicated in the figures. Ensure that the cabinet where the oven is to be installed is able
to support the weight of 30 kg for FI-A36 FI-45 FI-60 FI-NB60 FI-FTO60 FI-
65; 45 kg. for FI-90 , FI-88 and FI-70; 70 kg for FI-TWIN. For the opening in the
cabinet follow the respective dimensions of the type of oven purchased, indicated in
fig.01 for FI-60 FI-NB60 FI-FTO60, fig.02 for FI-65 fig. 03 for FI-70, fig.04 for FI-
88 fig.05 for FI-90 fig.06 for FI-TWIN fig.07 for FI-A36 and fig.8 for FI-45.
It is necessary to create an opening in the rear part of the bottom of the cabinet or in the
oven support shelf, to allow sufficient air to circulate for the cooling of the oven during
functioning.
Ensure the oven is safely installed inside the cabinet. Use screws A for fixing of the
oven.
ELECTRIC CONNECTION OF THE OVEN
Make sure that the electric current has been removed before connecting the oven to
the electric mains.
Attention: During the electrical connection ensure the flexible cable is not damaged. If
it is not intact, to avoid any risk, it must be completely replaced with a cable having the
same characteristics and only by qualified and skilled staff.
The oven requires single-phase alternate current 220-230-240 V~ 50-60 Hz, using
flexible cable. Ensure the household power supply can support the electric load of the
device. (see serial plate). The electric safety of this appliance is only assured if the same
is correctly connected to a system having efficient earth connection, according to the
legal standards in force.
In case of permanent connection to the electric mains, apply a bipolar switch dimensioned to the
corresponding charge, with an opening for every contact of at least 3 mm.
In models where present, the flexible cable is supplied without plug. The plug to be used
must be suitable for the electric load of the product and must comply with the current
regulations.
The installer must ascertain that the section of the socket cables is suitable to the power
absorbed by the oven, as indicated in the serial plate.
The connection socket must be easily accessible. Disconnection of the appliance from
the electrical supply must be permitted after installation is performed.