Operating Instructions and Installation Instructions

9880022302-EN-250717.doc
27
EN
N
FI TWIN Single-phase FI TWIN Two-phase
ASSEMBLY/REPLACEMENT OF THE POWER SUPPLY CABLE
If the supply cord is damaged, it must be replaced by the manufacturer, its service
agent or similarly qualified persons in order to avoid a hazard.
The electric cable must be kept secured to the terminal box by means of a cable fix so
that it cannot come out. Connect the line cable to terminal L the neutral cable to
terminal N and the yellow/green cable to the earth terminal . The yellow/green
cable must be longer than the other two by at least 20 mm.
Be careful that the electric cable does not pass near or comes into contact with the
surfaces that reach temperatures above 75°C.
EARTH CONNECTION
Installation, connection and earthing of the electric system must comply with the
European standard requisites and meet the provisions of the local standards in force.
This household appliance requires an earthing connection for protection against
short-circuits or electric dispersions. It must, therefore, be connected to an
appropriate electric socket. The earth cable must not be interrupted by the switch.
ATTENTION: DISCONNECT THE ELECTRIC POWER SUPPLY BEFORE
PERFORMING TECHNICAL ASSISTANCE OR MAINTENANCE ON THE
PRODUCT.
In case of replacement of the electric cable, ensure the use of an electric cable certified
according to the standards in force and suitable to the technical features of the product.
Use only flexible cables:
cable type H05RR-FH 3 x 1.5
for mod. FI TWIN use cable type H05RR-FH 3 x 2.5