7. Refer to Figure 4-7 and manually engage the trimmer solenoid pin into the
trimmer cam groove by pushing the protruded end of the pin inward with a flat
bladed screw driver.
8. Hold the trimmer solenoid pin in as you continue to apply clockwise rotation to
the Z drive pulley/belt. Rotate the head shaft at least one full revolution.
You should not feel any restrictions during the rotation. If you do, you may have a
damaged trimmer cam or trimmer solenoid.
NOTE: You may remove the trimmer solenoid for inspection or replacement.
However, when the trimmer solenoid mount is moved, the movable knife
home position may become mis-adjusted.
9. Refer to the procedure for replacing the trimmer solenoid and remove the
solenoid.
10. While the trimmer solenoid is removed, inspect the trimmer cam for damage. If
the cam is damaged beyond use, factory service is recommended to replace it.
11. Go to the movable knife home position adjustment procedure after the solenoid
is reinstalled.
12. Repeat this procedure to check again for unrestricted cam assembly movement.
Checking "Head Up" Position
Before checking/adjusting movable knife "home" or "select" positions, you should
check the cam positions at head up.
1. Remove the embroidery head rear bed cover to expose the trimmer camming
mechanisms shown in Figure 4-7.
WARNING! Keep clear of the moving parts that are exposed
during the operation of the next step(s).
2. Go to the HEAD TIMING MENU and press to turn HEAD TIMING ON. Put the
heads to the "head up" position by pressing the key combination.
3. Locate the holes in the rear of the cams (see Figure 4-7) and check that they are
facing nearly straight upward. If the holes are not facing close to straight
upward, the select position may require adjustment. Refer to the select position
adjustment in this chapter.
4 - 12 Trimmer Adjustment Procedures
EMT 10T Technical Manual Melco Embroidery Systems