Specifications

GREEN (all should be ON)
1) I/O FPGA (I/O IC on CPU configured OK at startup)
2) Control FPGA (Control IC on CPU configured OK at startup)
3) +5V (Power OK from CPU)
4) +6V (Isolated) OK
5) +36V OK (see note **)
6) +24V OK
7) -12V OK
8) +12V OK
9) +5V (+12V based) OK
10) +5V (+24V based) OK
RED
(all should be OFF)
1) Estop Engaged
2) Light Fuse Blown
3) Bobbin Fuse Blown
4) Grabber Motor Current Limit Error
5) Color Change Motor Current Limit Error
6) Z Motor Current Limit Error
7) Y Motor Current Limit Error
8) X Motor Current Limit Error
9) Y Home not functioning
10) X Home not functioning
GREEN
(2) through (5) ON, others as indicated)
(ON only at Head Up) Z Index (1
Watch Dog (2
(see note ***) Z Hall (3
(see note ***) Y Hall (4
(see note ***) X Hall (5
Color Chg & Grabber Motor Brakes (6
XYZ Motor Brakes (7
OFF when Grabber is Home (8
Y Home (9
X Home (10
1 2 3 4 5 6 7 8 9 10 1 2 3 4 5 6 7 8 9 10 TEST POINTS *
-12 VDC *
+12 VDC *
+5 VDC *
GND
ISO RET (Isolated GND)
+6 VDC ISO *
+36 VDC *
+24 VDC *
TEST POINTS *
* TEST POINT Voltage Tolerances
+6 VDC ISO (+5.6 to +6.1 VDC)
+36 VDC [without load] (+30 to +37 VDC)
+36 VDC [with 20-100% load] (+34.2 to +37.8 VDC)
+24 VDC (+22.8 to +25.2 VDC)
-12 VDC (-10.8 to -13.2 VDC)
+12 VDC (+11.4 to +12.6 VDC)
+5 VDC (+4.9 to +5.1 VDC)
Note ** +36 VDC
When the peripheral is first
turned on and before the
program is downloaded,
the +36.0 VDC LED may be
blinking. This is normal. But
after the machine initializes,
and the motors become
energized, if the blinking
does not stop the power
supply may be marginal.
YELLOW
(conditions as indicated)
10) Cut Home #1 (OFF when Home)
9) (disregard, 4-Head Only)
8) (disregard, 4-Head Only)
7) (disregard, 4-Head Only)
6) UTC #1 (should flicker while stitching)
5) (disregard, 4-Head Only)
4) (disregard, 4-Head Only)
3) (disregard, 4-Head Only)
2) Standard Cap Frame (ON when Installed)
1) Wide Angle Cap Frame (ON when Installed)
(9) & (10) ON - one side of axis center,
OFF - other side of axis center
Note *** Hall - Sensors in the
motor which indicate defective
(dead spot) sections in the
motor. Only OFF at dead spot
positions in the motor rotation.
(8) will flicker
during trim
GREEN
RED
GREEN YELLOW
1 2 3 4 5 6 7 8 9 10 1 2 3 4 5 6 7 8 9 10
(6) & (7)
ON until motors
initiated, then OFF
EMT 10T
Figure 1 - 3
Configuration Procedure 1 - 7
110291-01, Rev D 1. Introduction