Specifications

10. Orient the connector on the encoder cable so the outside black wire is to the
right and will plug into pin 1 of the new encoder (see inset in Figure 3-3). Push
the encoder cable connector onto the new encoder.
CAUTION! If the Z shaft encoder is replaced, DO NOT OPERATE THE
EMBROIDERY PERIPHERAL until the new Z shaft encoder is properly
calibrated!
11. Calibrate the Z encoder per the following procedure.
Calibration
CAUTION! Failure to properly calibrate the Z shaft encoder after
replacing it, may cause damage when attempting to operate the
machine.
Note: This procedure requires the use of a special service tool: the Melco 10 needle
head up fixture (p/n 995673-01).
1. Install the Z shaft encoder as described previously.
Note: To perform this procedure, it is important that the peripheral does
not "download." To insure this condition remove the network cable (or
boot disk if being used).
Shaft Pulley
Z Encoder
Z Motor
Z Encoder Cable
Shaft Coupler
head Z shaft coupler cap head screws (B)
Jam Nut
Z encoder shaft coupler cap head screws (A)
54321
green
black
black
red
white
orientation of
encoder cable
connector according
to wire locations
Z encoder
Figure 3 - 3
3 - 6 Z Shaft Encoder
EMT 10T Technical Manual Melco Embroidery Systems