7. Remove the clamping devises from each end of the V-rail and reinstall all covers
that were removed during the procedure.
8. Power up the peripheral and position the needle case to needle #5.
9. Go into the Head Timing menu and bring needle #5 down slowly, using the
key.
10. Check for the needle centered in the needle plate hole.
11. If a slight recentering is required:
a) Loosen the four needle case screws installed and tightened in steps 4 and 5.
b) Reposition the needle case within the tolerances of the screw holes.
c) Retighten the screws, crossing diagonally during the tightening sequence to
enable even tightening.
needle case
locator socket
head cap screw
needle case
bearing
retainer
plate
socket head cap
screws securing
needle case
Figure 3 - 30
3 - 34 Needle Case