HEM-637-E2 EN 7/8/10 9:17 AM Page 2 R7 English Table of Contents Before measuring your Blood Pressure Notes on safety Names and functions of the parts How to insert the batteries How to set the Date and Time 3 4 5 6 7 How to measure Blood Pressure correctly How to obtain a correct posture How to measure Blood Pressure How to use the Memory function How to use the Graph function How to change the settings Auto memory Position sensor Left or right wrist measurement Alarm Time Delete data Reset settings
HEM-637-E2 EN 7/8/10 9:17 AM Page 3 R7 English Before measuring your Blood Pressure Notes on Safety Please read thoroughly before using this monitor. • The warning signs and the sample icons shown here are listed for you to use the product safely and correctly as well as to prevent the risk of damage to you and others. • The icons and meanings are shown as follows. Warning sign Caution Contents Indicates matters in which bodily harm or material damage* may arise as a result of incorrect handling.
HEM-637-E2 EN 7/8/10 9:17 AM Page 4 R7 English Notes on safety Important instructions for obtaining meaningful readings • Avoid eating and drinking (alcohol), smoking, sport and taking medicines before measuring your blood pressure as this could affect your blood pressure level. • Before you start sit comfortably on a chair and relax. It is recommended to check your blood pressure at least twice a day, in the morning after getting up and in the evening after work, or as advised by your doctor.
HEM-637-E2 EN 7/8/10 9:17 AM Page 5 R7 English Main unit Batteries for monitoring Storage case (Two LR03 alkaline batteries) Instruction Manual Blood pressure pass Guarantee card Names and functions of the parts Main unit Wrist Cuff Battery Cover 5
HEM-637-E2 EN 7/8/10 9:18 AM Page 6 R7 English MEMORY RECALL button Push this button to see the measured values stored in the monitor. Systolic Blood Pressure Display Diastolic Blood Pressure Display Date/Time Display GRAPH CALL button Push this button to see the graph. Mark Displayed when a stored measurement is shown. Pulse Display Button Push to move the displayed item forward. Push to move the displayed item backward.
HEM-637-E2 EN 7/8/10 9:18 AM Page 7 R7 English With new batteries (long life alkaline batteries) you are able to measure app. 300 times under normal conditions. Please switch off the monitor after using it. If you forget to switch the monitor off it will switch off itself after app. 2 minutes. Please take the batteries out of the monitor if you intend not to use the monitor for a long period (app. 2 months).
HEM-637-E2 EN 7/8/10 9:18 AM Page 8 R7 English 4) Place the cuff over your left wrist with your thumb facing upwards. Leave app 10-15 mm between the cuff and the bottom of the palm of your hand as shown in the figures. 5) Pull the wrist cuff upward and close the cuff firmly with the Velcro tape as shown. 10~15mm 1 2 3 You can use your OMRON R7 also on your right hand after selecting right wrist measurement in the SETTING MODE.
HEM-637-E2 EN 7/8/10 9:18 AM Page 9 R7 English How to obtain a correct posture Achieving a correct posture before measuring your blood pressure is important since an incorrect posture might give you incorrect readings. To achieve a correct posture please follow the instructions (see pictures): 1) Sit down and stretch your back. 2) Relax yourself by relieving the stress from your shoulders and arms. 3) Breath several times deeply and return to natural respiration.
HEM-637-E2 EN 7/8/10 9:18 AM Page 10 R7 English How to measure Blood Pressure Sustain your elbow with your other hand or a table to avoid movement. • Adjust the height of your wrist by using your elbow as a fulcrum. When the ( ) will reach the ( ) sign you will hear a beeping sound indicating that your blood pressure monitor is at the correct height (heart height). The ( ) sign will change in the ( ) sign and the measurement will start.
HEM-637-E2 EN 7/8/10 9:18 AM Page 11 R7 English How to enlarge the reading The results will be shown on your display. By pushing the ( ) buttons you can enlarge the readings. How to use the Memory function Your OMRON R7 blood pressure monitor is able to store maximum 90 measurements including date and time. When your blood pressure monitor is holding 90 measurements the oldest will be deleted to store a new measurement. Press the (M) memory button when your blood pressure monitor is switched off.
HEM-637-E2 EN 7/8/10 9:18 AM Page 12 R7 English How to use the Graph function This monitor has the possibility to display the stored measurements as a graph. In order to get a clear history of your blood pressure the measurements are put in time zones: • Morning: Measurements made between 0:00 and 9:59 • Daytime: Measurements made between 10:00 and 17:59 • Evening: Measurements made between 18:00 and 23:59 The last measurement in each time zone will be displayed.
HEM-637-E2 EN 7/8/10 9:18 AM Page 13 R7 English Explanation of the graph display When the GRAPH button is pushed the latest measurement will appear in a flashing display. In the example the measurement is made on January 31 at 22:40. The graph shows 140 mmHg for systolic and 95 mmHg for diastolic (top and bottom of vertical bar) and a pulse rate of 90 beats a minute. When you push the memory button in the graph display the details of the measurement will appear.
HEM-637-E2 EN 7/8/10 9:18 AM Page 14 R7 English • If you push the SETTING button while the power is turned off, the Setting Screen is displayed in the order shown in the picture. • You can select the setting or set the date and time with the buttons. • To finish the setting, push the on/off button. Automatic Memory Setting (Refer to Page 14.) Position Sensor Setting (Refer to Page 15.) Measuring (Wrist) Setting (Refer to Page 15.) Alarm Setting (Refer to Page 15.) Reset Settings (Refer to Page 16.
HEM-637-E2 EN 7/8/10 9:18 AM Page 15 R7 English Position sensor The position sensor of your OMRON R7 can be switched ON or OFF. In the factory preset the position sensor is enabled. If the position sensor is switched ON you can choose to have the optimal wrist height supported by an acoustic sound (SIGNAL ON or OFF).
HEM-637-E2 EN 7/8/10 9:18 AM Page 16 R7 English Time You can change the time and date setting of your blood pressure monitor. When reaching the time screen you will see the Gregorian calendar. The year will be flashing. 1. By using the ( ) buttons you can set the current year. 2. By pushing the SET button you will lock the year and proceed to the next setting. Time Screen For setting the month, date and time repeat step 1 and 2. After setting the minutes you will proceed to the DELETE DATA screen.
HEM-637-E2 EN 7/8/10 9:18 AM Page 17 R7 English What is Blood Pressure? Blood is pumped to artery by the beat (contraction and expansion) of a pump called the heart. The pressure to pump out blood to artery is called the "systolic blood pressure." The pressure when the heart expands as the blood having circulated the whole body returns is called the "diastolic blood pressure." Health and blood pressure Blood pressure fluctuates being affected by everyday life and age.
HEM-637-E2 EN 7/8/10 9:18 AM Page 18 R7 English Hypertension guide The World Health Organization (WHO) and the International Society of Hypertension (ISH) established the Blood Pressure Classification. Use this Classification as the guide to know the state of your blood pressure. However, if you are concerned with your blood pressure, be sure to follow the instructions of your doctor.
HEM-637-E2 EN 7/8/10 9:18 AM Page 19 R7 English Diseases influencing blood pressure values Diabetes, hyperlipemia, or hypertension accelerates arterial sclerosis, which causes dangerous disease such as cerebral apoplexy or myocardial infarction or induces arterial stenosis or peripheral circulatory disorder. In these cases, the wrist and brachial blood pressure values may differ greatly. (Even in healthy people, a difference of 20 mmHg may occur if the measuring conditions are not proper.
HEM-637-E2 EN 7/8/10 9:18 AM Page 20 R7 English Error indication If the measurement is not made correctly, the following error can be displayed. Error Cause How to correct You moved your wrist during measurement. Measure your blood pressure again without moving your wrist until the measurement is completed. (Refer to Page 10.) You moved your arm or body, or talked during measurement. Measure your blood pressure again without moving your arm or body. (Refer to Page 10.
HEM-637-E2 EN 7/8/10 9:18 AM Page 21 R7 English Troubleshooting Trouble Nothing is displayed when you push the on/off button. Measurement cannot be made. Or the blood pressure values are displayed abnormally high (low). Possible cause How to correct Batteries are worn out. Replace the batteries with new ones. (See to Page 6.) The directions of polarities of inserted batteries (+ and -) are wrong. Insert the batteries correctly. (Refer to Page 6.
HEM-637-E2 EN 7/8/10 9:18 AM Page 22 R7 English Spare parts and accessories OMRON considers, due to the used high company and quality standards, the main unit as a non-serviceable part because of the necessity of proper calibration after replacement of hightech components. The cuff can be replaced by an authorised expert.
HEM-637-E7 Cover_24101102 R7 GB 12/01/06 21:01 ページ 2 Manufacturer OMRON HEALTHCARE Co., Ltd. 53, Kunotsubo, Terado-cho, Muko, Kyoto, 617-0002 JAPAN EU-representative OMRON HEALTHCARE EUROPE B.V. Scorpius 33, 2132 LR Hoofddorp THE NETHERLANDS www.omron-healthcare.com EC REP Production facility OMRON (DALIAN) CO., LTD.