Operating instructions
PERFECT page 19
10.1  Closure commands for ramp segments
NEXT Follow-on with next programme segment.
SPWT (T)
SET-POINT WAIT
Wait until the setpoint temperature is reached.
The oven only starts the next programme segment when the programmed 
setpoint temperature has been reached, even if the programmed heating 
time has already elapsed.
LOOP Ramp repeat function.
The set programme is repeated after passing through all programmed 
segments.
1-99 = repeats
cont = continuous repeat function
HOLD End of programme without switching off the heating; temperature and 
all other settings (e.g. air valve) are maintained.
END End of programme, heating is switched off, all other settings (e.g. air 
valve) are reset to base status.
The  programme  segments  are  linked  together  by  the  segment  closure  command.  These  commands 
therefore control the programme sequence.
°C
Ramp
closure 
command 
ramp 
segment 1 
spwt (t)
t=time
segment 1
closure 
command 
ramp 
segment 2 
next
closure 
command 
ramp 
segment 4
next
closure 
command 
ramp 
segment 5
end
closure 
command 
ramp 
segment 3 
spwt (t)
segment 3
segment 1
segment 5
segment 4
delayed 
programme start