Service manual

6-36 Engine Electrical Engine
2006 LSSV Service Manual Supplement
4. Install the rubber cover onto the rear of the positive cable
connection.
5. Position the slave receptacle cover onto the rear of the
bracket.
6. Install the fasteners (2) onto the slave receptacle (3) and
the slave receptacle cover (1).
Tighten
Tighten the bolts to 8 N•m (71 lb in).
7. Install the slave receptacle cover (1).
8. Connect the battery cables. Refer to Battery Cable
Disconnect/Connect Procedure.
Vehicle Load Disconnect Switch – MEGA
Fuse 175 Amp/MIDI Fuse 50 Amp
Replacement
Removal Procedure
1. MEGA Fuse 175 Amp (1).
2. MIDI Fuse 50 Amp (2).
Caution: Refer to Battery Disconnect Caution in Cautions
and Notices.
3. Disconnect the battery cables. Refer to Battery Cable
Disconnect/Connect Procedure.
Notice: MEGA Fuse 175 Amp cover shown, MIDI Fuse 50 Amp
cover same removal.
4. Remove the fuse cover (1).