Flue and Chimney connection to your stove (continued)
If it is found that there is excessive draught in the chimney then either an adjustable flue damper or alternately a draught
stabiliser should be fitted. The adjustable flue damper should not close off the flue entirely but should in its closed position
leave a minimum continuous opening free area of at least 20 % of the total cross sectional area of the flue or flue pipe.
Adequate provision e.g. easily accessible soot door or doors must be provided for sweeping the chimney and connecting flue
pipe
Your appliance needs to be maintained routinely, the throat plate/baffle should be cleaned regularly (monthly) . The flue
pipe can be cleaned using a flexible brush. Only Use a damp cloth on external surfaces. Over time the glass may become
dirty, clean with a damp cloth and polish off with damp cloth. If the stove has not been used for some time the flue should
be checked for blockages before use.
Do not modify the appliance; only use spares authorised by the manufacturer.
B
C
E
A
D
F
A B C D E F F Ped
Loxton 3 525mm 380mm 280mm 125mm 107mm 400mm N/A
Loxton 5 606mm 490mm 320mm 125mm 115mm 480mm N/A
Loxton 6 606mm 490mm 340mm 125mm 115mm 480mm 825mm
Loxton 8 660mm 490mm 400mm 150mm 115mm 530mm 825mm
Loxton 10 660mm 705mm 400mm 150mm 110mm 530mm 905mm
Churchill 5 606mm 490mm 380mm 125mm 115mm 480mm N/A
Churchill 6 606mm 490mm 400mm 125mm 115mm 480mm 825mm
Churchill 8 660mm 490mm 460mm 150mm 115mm 530mm 825mm
Churchill 10 660mm 705mm 460mm 150mm 110mm 530mm 905mm
Sqabox unO 606mm 490mm 320mm 125mm 110mm 480mm N/A
Sqabox duO 606mm 490mm 340mm 125mm 110mm 480mm N/A