Operating instructions
 LISTED DIRECT VENT GAS FIREPLACE HEATER POÊLE AU GAZ HOMOLOGUE’, A AÉRATION DIRECTE 
NOT FOR USE WITH SOLID FUEL (NE DOIT PASÉ UTILISÉ AVEC UN COMBUSIBLE SOLIDE) 
Manufactured by (Fabriqué par): JOHNSON GAS APPLIANCE CO. CEDAR RAPIDS, IOWA 
CERTIFIED FOR CANADA HOMOLOGUÉ POUR LE CANADA 
 Tested to (Testé aux normes) ANSI Z21.88-2002 • CSA 2.33-2002 • CAN/CGA 2.17-M91 and ANSI Z21.50-1996. 
WARNING: Improper installation, adjustment, alteration, service or maintenance can cause property damage, personal injury, 
or loss of life. Refer to the owner's information manual provided with this appliance. Installation and service must be per-
formed by a qualified installer, service agency or the gas supplier. For use with glass doors certified with the appliance only. 
Do not operate with glass panel(s) removed, cracked, or broken. This vented gas fireplace heater is not for use with air filters. 
Register kit may be used. 
MISE EN GARDE: Installation, réglage, modification, entretien ou depannage non appropriés pourront causer des blessures 
ou des dommages materiels. Réferéz-vous au manuel du proprietaire fourni avac cet appariel. Pour assistance ou rensei-
gnements complémentaires, veuillez consulter un installateur expérimenté, une agence dé depannage/entreitien ou cotre 
compagnie gaziére. Pour utilisation avec les portes en verre certifiée l'appareil suelement. Ne pas opérer avec le verriére 
enlever, craquelure, brise. 
 NATURAL GAS 
(Gaz Naturel) 
PROPANE GAS 
(Gaz de petrole liquefie (GPL)) 
Input Rating (Btu/hr) 0 - 610 m (Entrée nominale)  45,000  40,000 
Min. Input Rating (Btu/hr) 0 - 610 m (Minimale En-
trée nominale) 
6,500 5,000 
Orifice 0 - 610 m (Orifice)  Front #44 Rear #35  Front 3/64" Rear #52 
Orifice 610 - 1370 m (Orifice)  Front #45 Rear #35  Front 3/64" Rear #53 
Maximum output (Btu/hr) (Sortie maximale)  32,400  28,800 
Manifold Pressure (in w.c./kPa) (Pression au collec-
teur) 
3.5/0.87 10.0/2.5 
Manifold Pressure, low (in w.c./kPa) Pression d'en-
trée minimale) 
1.7/0.42 3.6/0.90 
Minimum Inlet Pressure (in w.c./kPa) (Pression d'en-
trée minimale) 
5.0/1.25 11.0/2.75 
This appliance is only for use with the type of gas indicated on the rating plate and may be installed in an afrtermarket, per-
manently located manufactured (mobile) home where prohibited by local codes. See owner's manual for details. This appli-
ance is not convertible for use with other gases, unless a certified kit is used. 
Cet appareil sera installé conformémént avec les codes locaux, le cas écheant. Si aucun code n'existe, suivez la norme ANSI 
Z223.1 ou la norme CAN/CGA (ACNOR)-B149.  
MINIMUM CLEARANCES TO COMBUSTIBLE CONSTRUCTION      Unit to adjacent sidewall   10 in. (254mm)
  Unit to floor      0 in. (0mm)    Vent to enclosed top     3 in. (76.2mm) 
Unit to enclosure sidewall    1 in. (25 mm)    Vent to enclosed side     14-3/4 in. (375mm) 
Unit to enclosure back wall   1/2 in. (13mm)    Wall Pass-Through to framing   0 in. (0mm) 
Unit top to ceiling     14-1/4 in. (374mm)    Mantle above discharge air opening   13 in. (330mm)   
CAUTION: Hot while in operation. Do not touch. Keep children, clothing, furniture, and flammable liquids or vapors away.     
ATTENTION: L'appareil est chaud lorsqu'il fonctionne. Ne pas toucher l'appareil. Survieller les enfants. Garder les véte-
ments, les meubles, l'essence ou autres liquides a capeur inflammables loin de l'appareil. 
Electrical Rating (Courant nominal): 120 volts 60 hertz 1.5 amperes 
DO NOT REMOVE OR COVER THIS LABEL VEILLEZ Á NE JAMAIS ENLEVER NI DISSIMULER CETTE ÉTIQUETTE 
MODEL: DXV-45 
  WH# __________________ 