MENDOTA WARRANTY QUALIFICATION & SERVICE REFERENCE FORM
As a part of Mendota's on-going program of customer satisfaction, this Form verifies proper installation and operation. It is important
as a reference for future service. It insures long life and trouble-free operation of Mendota fireplaces & stoves and qualifies the owner
for Mendota's lifetime limited warranty. Owner should sign Form when completed and mail a copy along with Warranty Registration
to Mendota. Optionally, please register at our website at: WWW.JOHNSONGAS.COM/MENDOTA-REGISTRATION.ASP
HOME OWNER: ________________________________ DEALER: ________________________________
ADDRESS: ____________________________________ ADDRESS: _______________________________
CITY/STATE/ZIP: ______________________________ CITY/STATE/ZIP: _________________________
SIGNATURE: __________________________________ PHONE: _________________________________
MODEL #: DXV-35 SERIAL #: ___________ DATE INSTALLED: ________________________
Mendota direct vent fireplaces are sophisticated, hi-tech gas appliances. All installation and operating instructions
must be carefully
followed. The DXV fireplace
must be installed and serviced by a qualified Mendota approved service person.
REF: MENDOTA DXV INSTALLATION MANUAL
APPROVED VENT PIPES AND VENT CAP INSTALLED - Per Manual.
Vent pipes must be fully twist-locked and leak proof.
Check minimum and maximum vertical / horizontal and vent runs.
1000ºsealant must be used on inner joints at adjustable pipe sections
.
CHECK FOR PROPER CLEARANCES TO COMBUSTIBLES & VENT LOCATIONS - Per Manual
INSTALL PROPER SIZE GAS LINES - CHECK FOR GAS LEAKS - Per Manual
CHECK FOR CORRECT GAS PRESSURE AT MANIFOLD - Per Manual
a. 3.5 Inches Water Column Maximum - Nat. Gas
b. 10.5 Inches Water Column Maximum - L.P. Gas
TAKE COMBUSTION SYSTEM MILLIVOLT READINGS [See Manual pg.. 45
a. Pilot only - [Minimum Millivolts 325] Reading: ___________________________
b. Main burner operating - [Minimum Millivolts 100] Reading: ___________________________
CYCLE BURNERS ON/OFF FOR PROMPT IGNITION - Per "LIGHTING INSTRUCTIONS"
Burner must light IMMEDIATELY - Flame must travel promptly around "curve" & light burner.
INSTALL LOGS AND ADJUST FLAME - Per Manual
Proper pilot flame impingement on thermopile & burner - Air shutter opening: 1/8" - 1/4" Nat. Gas - 1/2" LP
Check that flame is "stable" and is not "lifting" off burner
BRIEF OWNER ON OPERATION AND MAINTENANCE OF UNIT
Light Pilot Operate Burner Explain blower "delay" operation
Optionally, please register at our website at: WWW.JOHNSONGAS.COM/MENDOTA-REGISTRATION.ASP
WARRANTY REGISTRATION
Your Name _______________________________________________________________________
Address __________________________________________________________________________
City ________________________________________ State______ Zip ______________________
Dealer (Place of Purchase) ___________________________________________________________
City ________________________________________ State______ Zip ______________________
Date of Purchase _______________________ Serial Number _______________________________
Purchaser's Signature _______________________________________________________________
MENDOTA DXV-45 DIRECT VENT FIREPLACE