Operating instructions
Part #85-03-00855
2
SPECIFICATIONS
MODEL E-FV-44i
High Fire - Adj. to - Low Fire
BTUH ....................................................NAT. GAS 40,000 ----- 29,000
BTUH ....................................................L.P. GAS 40,000 ----- 33,000
MAIN ORIFICE……REAR BURNER: #42 NAT. GAS [#55 L.P. GAS] – FRONT BURNER: #45 NAT. [#55 LP]
EFFICIENCY .....................................EXCEEDS D.O.E. EFFICIENCY REQUIREMENTS (A.F.U.E.)
FLUE VENT LINER ............................CO-LINEAR - 4” DIAMETER EXHAUST & 3” DIAMETER INLET
NET WEIGHT ...................................195 lbs.
SAFETY ...........................................AGA CERTIFIED, ELECTRONIC IGNITION IPI SYSTEM
ACTIVATED WITH THERMOSTATIC REMOTE CONTROL.
GAS REQUIREMENTS .......................SUPPLY PRESSURE: GAS INLET: 3/8" N.P.T.
NAT. GAS: 7" W.C. [5.0" W.C. MIN., 11" W.C. MAX.]
L.P. GAS: 11" W.C. [11" W.C. MIN., 13" W.C. MAX.]
ELECTRICAL REQUIREMENTS ...... 120 Volts AC, 2 Amps (minimum line voltage allowed 110 Volts AC)
LISTINGS - INTERTEK TESTING SERVICES TESTED TO: ANSI Z21.88-2005 – CSA2.33-2005 – CAN/CGA 2.17-M91
Gas appliances must be tested and certified by a nationally recognized testing and certification agency to American Na-
tional Standards Institute - ANSI Gas Appliance Safety Standards. . The Mendota Gas Fireplace Insert has been tested
and certified by Intertek Testing Services. 8431 Murphy Drive, Middleton, WI 53562.
INSERT INCLUDES CERAMIC COMBUSTION SYSTEM, PREMIUM 8-PIECE FIBER LOG SET & COALS, NEO-CERAM GLASS,THERMOSTATIC REMOTE
ELECTRONIC IGNITION, AGA CERTIFIED SAFETY SYSTEM.