F FULLVIEW W DIRECT T VENT GAS G FIREPLACE IN NSERT HEATER Mod del FV-33 3i HOME OWN NER’S MANUAL M L D DOCUMENT NO. FV33i-O OM-1110 Do not store orr use gasolin ne or other flammable vap pors and liqu uids in the viicinity of this s or any oth her appliance e. WH HAT TO DO IF YOU SMELL GAS G Open window ws. Do not touch h electrical sw witches. Do not try to o light any app pliance. Extinguish any a open flame e. Do not use the phone in your y building.
Table of Contents SAFETY AND WARNING INFORMATION .......................................................................................... 3 SPECIFICATIONS ................................................................................................................................ 4 CONGRATULATIONS ......................................................................................................................... 5 BUILDING PERMIT AND INSTALLATION INSPECTION APPROVAL REQUIREMENTS .................
SAFETY AND WARNING INFORMATION READ and UNDERSTAND all instructions carefully before starting the appliance. FAILURE TO FOLLOW these instructions may result in a possible fire hazard and will void the warranty. Any safety screen or guard removed for servicing must be replaced before operating this appliance. DO NOT USE this appliance if any part has been under water.
SPECIF FICATION NS MODE EL FV-33i Inputt rating (Btu/h hr) 0-610 m Minim mum input (Bttu/hr) 0-610 m Orificce size (DMS) 0-610 m (frront/rear) Manifold pressure e (in. w.c./kPa a) > High Fire Manifold pressure e (in. w.c./kPa a) >Low Fire Minim mum inlet pre essure (in. w.c c./kPa) Air sh hutter settingss (in) Natural Gas 3 31,000 1 10,000 49/45 3 3.5/0.87 1.7/0.42 5 5.0/1.24 1/16” Propane Gas P 31,000 13,000 3 /64”/ 3/64” 10.0/2.49 6.3/1.57 11.0/2.74 ¼” CIENCIES ................................ .
CONGRATULATIONS You are the owner of a world-class heat producing gas direct vent sealed combustion fireplace insert. This elegant, highly efficient Fireplace will be a constant source of comfort and fascination. It will be the focal point of beauty and interest in your home. The Mendota Gas Fireplace insert is a true heating appliance incorporating the traditional aesthetics of fireplace fire viewing with the controllability and fuel efficiency of a home gas furnace.
BEF FORE YO OU BEGIN N Read this entire maanual before yo ou use your new w fireplace (esspecially the seection “Safety Precautions” on o page 2). Faailure to follow w perty damage, bodily b injury, or o even death. the innstructions mayy result in prop Rem mote Conttrol Transmitter Functions NOT TE: The Rece eiver will “beep p” once everyy time a Remote Transmittter Key is pressed, signalin ng that the comm mand has bee en received.
RE EMOTE TR RANSMIT TTER OPERATING G INSTRU UCTIONS TO TURN T ON THE E APPLIANCE E: 1. P Press the ON//OFF button. The transmittter display will w show all acctive icons on n the screen. 2. Select S the The ermostat Mod de by pressing g the Thermo ostat Key: OFF (meaning Manual M M Mode), ON (m meaning norm mal Thermosta at) or Smart (m meaning Sma art Mode). a In OFF (M a. Manual Mode)), the appliancce will ignite and a start on HI. H b In ON (No b.
MA ANUAL BY YPASS OF O THE RE EMOTE SYSTEM S If the e remote transmitter is mis splaced or losst, the applian nce can be turrned on manu ually by sliding the three e position slide er switch on the t receiver to o the ON possition. This willl bypass the remote contro ol featu ure of the systtem and the appliance’s a m main burner wiill turn on. The e fan will run at its maximu um spee ed and the Acccent Light ma ay turn on.
“FIRST TIME” PILOT LIGHTING INSTRUCTIONS IMPORTANT: Be sure all items on "INSTALLATION CHECK OFF LIST" in the Installation Manual have been completed! CAUTION: If the pilot goes out, be sure to wait a minimum of five minutes before attempting to relight the pilot. 1. Make certain that any manual gas supply shut-off valves located upstream of fireplace are open and the receiver and the remote control transmitter are in the "OFF" position.
INITIALIZING THE REMOTE CONTROL SYSTEM (Synchronizing Receiver and Transmitter) BLUE LCD DISPLAY WALL RECEIVER 3-POSITION SLIDER SWITCH PR G 1. Place 3-position slider switch in Receiver in the “Remote” position. 2. Locate “PRG” key on Receiver Face. Use the tip of a pen/pencil or a wire clip to push the PRG button. The receiver will beep 3 times indicating that it is ready to synchronize with a Remote Transmitter. 3. Push the “ON” key on the Remote Transmitter.
DOOR REMOVAL AND REPLACEMENT CAUTION: Do not operate the appliance with glass removed, cracked or broken. Replacement of the glass should be done by a licensed or qualified service person. Glass latch tool #HA-57-00743 is supplied with the unit. To Unlatch Glass Frame Latches: 1. Insert Glass Latch Tool into hole in latch (two latches exist at top of glass frame). 2. Pull Glass Latch Tool outward about 3/8”. 3. Rotate Glass Latch Tool 90 degrees. 4. Release Glass Latch Tool. 5. Remove Glass Latch Tool. 1.
BLOWER OPERATION AND WIRING WARNING: The Power Cord supplied with this appliance must be connected to a 3-prong grounded LIVE outlet. No switches, Light Dimmers or Fan Speed Control Devices are allowed within the same electric circuit as this appliance. Connect only to a LIVE outlet that is not controlled by any other switching device. Dual blowers are provided as standard equipment with this FV-33i Insert. The dual blowers have an air output rating of 210 CFM (in free air).
MENDOTA WARRANTY QUALIFICATION & SERVICE REFERENCE FORM As a part of Mendota's on-going program of customer satisfaction, this Form verifies proper installation and operation. It is important as a reference for future service. It insures long life and trouble-free operation of Mendota fireplaces & stoves and qualifies the owner for Mendota's lifetime limited warranty. Owner should sign Form when completed and mail a copy along with Warranty Registration to Mendota.
TAPE SHUT -------------------------------------------------------------------------------------------------------------------------------------------------------- POSTAGE NEEDED JOHNSON GAS APPLIANCE COMPANY 520 E AVENUE N.W.
MENDOTA EXTENDED LIFETIME PROTECTION AND LIMITED WARRANTY MENDOTA FV33I DIRECT VENT FIREPLACE INSERT Mendota Division of Johnson Gas Appliance Company, 520 E Avenue N.W. Cedar Rapids, Iowa 52405, extends this Extended Lifetime Protection and Limited Warranty to the original purchaser of a Mendota FV33I Fireplace, which is limited and used under normal home conditions. STANDARD WARRANTY: JOHNSON GAS APPLIANCE CO.
Johnson Gas Appliance Company 520 E Avenue N.W. - Cedar Rapids, IA 52405 Mendota Hearth Division WEBPAGE: www.johnsongas.com or www.mendotahearth.