Operating instructions

12 | Page
PLANNING THE INSTALLATION
When planning on appliance installation, it is necessary to determine the following information before installing:
Where the appliance is to be installed.
The vent system configuration to be used.
Gas supply piping.
Electrical Wiring.
Framing and finishing details.
Hearth Protection Pad Requirements.
Whether accessories such as a wall switch, remote control, and ceiling fan are desired.
Selecting Appliance Location
When selecting a location for your appliance, it is important to consider the required clearances to walls.
70
3
4
"
57-1/2"
19-5/8"
19-5/8"
48" MIN.
ROUGH FRAMING
WIDTH
27-5/8"
48" MIN.
ROUGH
FRAMING WIDTH
22-1/2"
In addition to these dimensions, also reference:
Mantel Clearances Section
Framing Dimensions Section
Venting Configuration Section
22-1/2"
MIN.
40-3/4"
48" MIN.
WARNING
FIRE RISK- ODOR RISK
Install appliance on hard metal or wood surfaces extending full width and depth of this fireplace.
An R-1 Rated Hearth Protection Pad [1-1/2” Thick Maximum] is required unless this fireplace is elevated.
For every 1” this fireplace is elevated, you may reduce the hearth pad depth by 1”. If this fireplace is ele-
vated 6” or higher no hearth protection pad is required.
Do NOT install this fireplace directly on carpeting, vinyl or any combustible material other than wood. Con-
struct chase to all clearance specifications in manual.
Locate and install appliance to all clearance specifications in manual.
ODOR RISK: DO NOT INSTALL ANY CEMENT BOARDS OF OTHER MATERIALS THAT CONTAIN
POLYMER BASED FIBERS OR OTHER POLYMER MATERIALS.