Operating instructions
12 | Page
PLANNING THE INSTALLATION
When planning on appliance installation, it is necessary to determine the following information before installing:
• Where the appliance is to be installed.
• The vent system configuration to be used.
• Gas supply piping.
• Electrical Wiring.
• Framing and finishing details.
• Hearth Protection Pad Requirements.
• Whether accessories such as a wall switch, remote control, and ceiling fan are desired.
Selecting Appliance Location
When selecting a location for your appliance, it is important to consider the required clearances to walls.
70
3
4
"
57-1/2"
19-5/8"
19-5/8"
48" MIN.
ROUGH FRAMING
WIDTH
27-5/8"
48" MIN.
ROUGH
FRAMING WIDTH
22-1/2"
In addition to these dimensions, also reference:
Mantel Clearances Section
Framing Dimensions Section
Venting Configuration Section
22-1/2"
MIN.
40-3/4"
48" MIN.
WARNING
FIRE RISK- ODOR RISK
• Install appliance on hard metal or wood surfaces extending full width and depth of this fireplace.
• An R-1 Rated Hearth Protection Pad [1-1/2” Thick Maximum] is required unless this fireplace is elevated.
For every 1” this fireplace is elevated, you may reduce the hearth pad depth by 1”. If this fireplace is ele-
vated 6” or higher no hearth protection pad is required.
• Do NOT install this fireplace directly on carpeting, vinyl or any combustible material other than wood. Con-
struct chase to all clearance specifications in manual.
• Locate and install appliance to all clearance specifications in manual.
• ODOR RISK: DO NOT INSTALL ANY CEMENT BOARDS OF OTHER MATERIALS THAT CONTAIN
POLYMER BASED FIBERS OR OTHER POLYMER MATERIALS.