TSD402 & TSD401 Installation & User Guide Compatible Equipment 9040 - Loudspeaker TS400 REM - Remote Keypad 496523 Issue A 1 of 10 TSD402 & TSD401
TSD402 & TSD401 Overview Introduction Control Panel Operation The TSD402 is a 5 zone (+ Final Exit) control panel with an integral Speech Dialler. It is ideally suited for domestic and small commercial installations, which require additional security through the communication of audio alarm messages over the telephone line. Operation and programming is carried out from the tactile rubber keypad on the control panel in conjunction with the 16 character LCD display.
TSD402 & TSD401 System Installation Battery Connection A 2.1Ah battery must be fitted to the control panel to allow the system to function during a mains fail condition. The TSD402 is equipped with a “Battery Protection” circuit so that if a battery is accidentally reverse connected or its voltage is below 8V, the “Battery Fault” LED illuminates. To clear the fault simply reconnect or replace the battery as appropriate.
TSD402 & TSD401 (See figure on page 3). Connections & Controls The main PCB has the following “Jumper Plugs” (JP), indicator LEDs and terminal connections. 5. Replace the TSD402 PCB. 6. Separate the remote keypad cover and base by using a screwdriver to push two of the clips (top or bottom) inwards from the cover retaining slots. Then lift the cover assembly away, noting that the PCB is connected to the under side of the cover. 7.
TSD402 & TSD401 Connection Diagram TSD402 EXTERNAL SOUNDER ALM RST - TRIGGER STROBE - TRG STB - HOLD OFF + HOLD OFF - + H/O - TAMPER RETURN - TMP - ALARM PIR To ZONE 1 AUX TAMPER TERMINAL STRIP (NOT SUPPLIED) L/S + AUX 12V - TAMPER 0V +12V To AUX -12V ZONE 5 (P A) To AUX +12V ZONE 4 (FIRE) ALARM PIR To ZONE 2 ZONE 3 (K/Sw) TAMPER 0V +12V ZONE 2 (ACCESS) To AUX -12V To AUX +12V ZONE 1 (ACCESS) To ZONE 3 FINAL EXIT SURFACE CONTACT NOTE: To FINAL EXIT FLUSH CONTACT To ZONE 5 (P.
TSD402 & TSD401 Initial Power-Up 1. Place a small screwdriver blade between the pins on the Control Panel PCB, marked FACTORY RESTART (located top left corner).
TSD402 & TSD401 Key Functions Engineer’s Reset 1. Enter Engineer’s code default 1234. The display will show ENG OPTION. you are now in Engineer’s Mode. 2. Press AWAY to return to unset. Loading Defaults 1. Power down panel mains and battery. 2. Place a small screwdriver blade between the pins on the control panel PCB, marked Factory Restart. 3. Power up panel battery and mains. 4. Remove the screwdriver blade. 5. Enter 1234. The display will show ENG OPTION.
TSD402 & TSD401 Engineers Quick Reference Programming Chart Key Function Action 1 Program Zones Press 1-6 to toggle zone types Press AWAY to end Options 2 View Log Press HOME to advance 3 Walk Test Activate detectors Press AWAY to end 4 Exit Time Enter 3 digit time Press HOME to accept Enter time between 001 - 255 (seconds) 5 Entry Time Enter 3 digit time Press HOME to accept Enter time between 001 - 255 (seconds) 6 Bell Duration Enter 3 digit time Press HOME to accept Enter time be
TSD402 & TSD401 User Options Introduction The ‘User 1’ passcode has the option to access the ‘User Options’ menu, this menu allows the user to test the system, change passcodes, change Home Area configuration, view the Event Log and program the Speech Dialler. To aid user programming, a brief description of each menu function has been printed underneath each number key. The figure below show the structure of the ‘User Options’ menu.
TSD402 & TSD401 Speech Dialler Programming (key 8) This option allows ‘User 1’ to program the Speech Dialler options. When this option is selected the system will stay in the ‘Speech Dialler’ programming menu until the ‘User 1’ passcode is entered. The figure below shows the basic menu structure: Speech Dialler Menu UNSET Enter first 3 digits of Passcode then (e.g.