STARTING SYSTEM SERVICE MANUAL NUMBER 26
Page 4A-6 90-861329--1 MARCH 1999
1. Ensure that the battery meets the following certain conditions before testing:
CAUTION
Test battery in well ventilated area as gases given off by battery are hazardous.
Battery must be 60 to 100°F (16 to 38°C).
Electrolyte level must be correct in all cells.
Battery must be at least half charged.
No obvious defects.
2. Place battery under heavy load (as during engine cranking or with a variable resistor
tester) and test cell voltage while under load:
a. Check voltage per manufacturers specifications.
b. If readings are low, recharge and retest.
c. If readings remain low, battery should be replaced.
Storage
1. Remove battery and clean exterior.
2. Check fluid level and fill if low.
3. Cover terminals and bolts with light coat of grease.
4. Set battery on wood or in carton; store in cool, dry place.
5. Check every 20 days for fluid level and slow charge.
IMPORTANT: A discharged battery can be damaged by freezing.