STARTING SYSTEM SERVICE MANUAL NUMBER 26
Page 4A-8 90-861329--1 MARCH 1999
Positive Current Flow
This is a general description of the positive current flow, from the battery and through the
system until the starter motor cranks.
• Battery to the solenoid switch (on starter) (RED battery cable).
• Solenoid switch to circuit breaker (RED).
• Circuit breaker to wire junction (RED-PUR).
• Wire junction to wiring harness plug (RED-PUR) terminal 6.
• Wiring harness plug to 20 amp fuse (RED-PUR).
• 20 amp fuse to ignition switch terminal I (RED-PUR). At this point ignition switch is turned
to START.
• Ignition switch terminal I to terminal C.
• Ignition switch terminal C to neutral start switch (YEL-RED). NEUTRAL START
SWITCH MUST BE AT NEUTRAL POSITION.
• Neutral start switch to wiring harness plug terminal 7 (YEL-RED).
• Wiring harness plug to starter solenoid (small terminal) (YEL-RED). Also ensure that
black (small terminal) wire is grounded.
• Starter solenoid is now “closed,” completing circuit between large terminal (RED-PUR)
and other large terminal (YEL-RED), causing starter motor to crank.