STARTING SYSTEM
SERVICE MANUAL NUMBER 26
90-861329--1 MARCH 1999 Page 4A-11
Testing/Replacement
1. Using continuity meter, connect test leads as shown and connect 12-volt battery with
jumper leads as shown.
72630
2. If no meter movement is present, replace solenoid.
Solenoid Switch
The solenoid switch, along with plunger, return spring, and shift lever, are completely sealed
and permanently mount-ed in the drive housing. If solenoid is defective, entire drive housing
must be replaced.
Periodic Inspection
Cranking motor and solenoid are completely enclosed in the drive housing to prevent
entrance of moisture and dirt. However, periodic inspection is required as follows:
1. Inspect terminals for corrosion and loose connections.
2. Inspect wiring for frayed and worn insulation.
3. Check starter mounting bolts for tightness.