Service manual

INSTRUMENTATION
SERVICE MANUAL NUMBER 26
90-861329--1 MARCH 1999 Page 4D-7
Battery Gauge
TESTING
1. Remove cables from battery and fully charge battery.
2. Connect negative () jumper lead from battery to gauge terminal G (GND).
3. Connect positive (+) jumper lead from battery to gauge terminal I or +12 V.
72750
Typical
4. Check gauge reading; if not as shown replace gauge.
72751
Typical
IndexIndex