Service manual

INSTRUMENTATION
SERVICE MANUAL NUMBER 26
90-861329--1 MARCH 1999 Page 4D-13
INSTALLATION
1. Apply Loctite Pipe Sealant with Teflon to threads of temperature sender.
2. Install sender in thermostat housing and tighten securely.
3. Connect TAN wire and coat with liquid neoprene.
a
b
a-TAN Wire
b-Water Temperature Sender
4. Refill closed cooling system with approved coolant as outlined in SECTION 6B.
DUAL STATION SENDER IDENTIFICATION
Sender will have 362-BC stamped on hex.