Service manual
SEAWATER COOLED MODELS SERVICE MANUAL NUMBER 26
Page 6A-6 90-861329--1 MARCH 1999
c. Place thermometer in container and position so that bottom of thermometer is even
with bottom of thermostat. DO NOT allow thermometer to touch container.
72675
a
b
c
a-Thermometer
b-Nylon String
c-Thermostat
IMPORTANT: When performing Steps d through f, water must be thoroughly agitated
to obtain accurate results.
d. Plug in tester and observe temperature at which thermostat opens (thermostat
drops off thread). Thermostat must open at specified temperature stamped on
thermostat.
e. Continue heat water until a temperature 25° F (14° C) above temperature specified
on thermostat valve must be completely open at this temperature.
f. Replace a thermostat that fails to meet all of the preceding tests.
Index