Owner`s manual

MAINTENANCE
79
7. Reinstall the fill/vent screw by turning it all the way in, then
loosen one and a half turns.
!
CAUTION
Fill/Vent screw must be backed out one and a half (1‑1/2) turns
(after bottoming out) to vent pump reservoir. Failure to loosen
the screw could damage the pump.
CHECKING TRANSOM INPUT SHAFT BEARING HOUSING
(DRIVE-LINE MODELS ONLY)
1. Remove the level indication (middle) pipe plug from the input
shaft housing. Ensure that the gear lube level lies at the
bottom of the hole. If not, remove the pipe plug from the top
of the input shaft housing.
a
b
12868
c
a - Top pipe plug hole (Fill)
b - Middle pipe plug hole (Check level)
c - Bottom pipe plug hole (Drain)
Tube Ref No. Description Where Used Part No.
Torco MTF Gear Oil
Transom input shaft
bearing housing
Obtain
Locally
2. Fill the input shaft housing through the top pipe plug hole with
Torco MTF Gear Lube until gear lube flows from the middle
pipe plug hole (do not overfill).