Operating Mode 05:
"Supervisor" Restricted Access Control
Description
This mode allows Level 2 cards to toggle Output K2, which, connected back to Input I2, restricts
Level 1 users. In this mode, Level 1 cards are accepted only if Input I2 sees a closed contact.
User Level Specifications
User Level 1
Cards having this User Level are rejected if the contact on Input I2 is open. If the contact on Input
I2 is closed:
A downward read will pulse Output K1.
User Level 2 (and 3)
A downward read will pulse Output K1, allowing entry.
An upward read will toggle Output K2.
Configuration
Input assignments:
Input I1 is connected to the request to exit (REX) contact.
Input I2 is connect to Output K2 and functions as the access control input. User Level
1 users are valid only when a closed contact is presented to this input.
Upper LED assignment:
The upper LED follows Input I2, displaying the status of the access control input:
Open Contact is displayed as RED
Closed Contact is displayed as GREEN
Operating Mode 06:
"Two-Door" Access Control
Description
This mode allows User Level 1 cards to activate Output K1, User Level 2 cards to activate Output
K2, and User Level 3 cards to activate either Output K1 or Output K2.
User Level Specifications
User Level 1
Both downward and upward read will pulse Output K1.
User Level 2
Both downward and upward read will pulse Output K2.
User Level 3
Downward read will pulse Output K1.
Upward read will pulse Output K2.
Configuration
Input assignments:
The inputs are not used in this mode.
Upper LED assignment:
Output K1 off is displayed as RED,
Output K1 on is displayed as GREEN