User manual

www.merging.com/hapi Page 72
Hapi User Manual
“48V power failure: all A/D 48V forced off until next reboot”
The attached error message is displayed when:
1. 48V is malfunctioning
2. If there is a short circuit on 48V
If a MAJOR (by MAJOR, we mean that the threshold of short-circuit detection requires at least 10
Preamp inputs to be shorted simultaneously) 48V Phantom Power Supply short circuit is detected, 48V
is forced off on all A/D channels and the following error message is displayed.
Note: 48V will be forced off until reboot.
Note: the user 48V settings are not affected i.e. the UI still shows the 48V as configured by the user.