Dynamics section
Show/Hide Dynamics section
Dynamics Section On/Off
Gain reduction display
The bar graph shows the gain reduction/increase generated by the Dynamics Section or by the
Expander. The range of the display can be switched between +-10 or 20 dB by clicking on the bar
graph. Scale markings in 1dB increments on the right-hand side of the bar graph make it easy to see if
the range is 10 or 20 dB.
Colors are used to denote a gain reduction or increase generated by either the compressor or the
expander:
Gain reduction by the Compressor is displayed in Red from top to bottom.
Gain increase by the De-Compressor is displayed in Pink from bottom to top.
Gain reduction by the Expander (normal or inverse) is displayed in Green from bottom to top. With
the compressor in inverse mode, the gain reduction of the expander is displayed in Green from top
to bottom
Threshold Level Control
Sets the level at which the compressor begins to act. If the input signal level exceeds the Threshold
Level, the gain is reduced (or increased in De-Compressor mode) in proportion to the setting of the
ratio control.
Ratio Control
Determines the proportion of gain reduction (or increase) for signals above the threshold level. If, for
example, the ratio is set to 2.00:1, in Compressor mode, if the input level rises by 2dBs above the
threshold level, the output level will only rise by 1 dB.
Attack Time Control
Controls the time the compressor takes to react when the input level exceeds the Threshold Level.
The lower the attack time, the faster the reaction.
Release and Hold Time controls
These two parameters work together and control the amount of time the compressor takes to react
when the input level is above the threshold level and starts fall. During the hold time the gain of the com-
pressor remains constant. After the hold time the gain of the compressor is changed at the rate set by
the release time. The lower the release time, the faster the reaction.
Show/Hide Dynamics Section
Gain Reduction Display
Threshold Level Control
Ratio Control
De-Compress Switch
Dynamics Section On/Off
Attack Time Control
Release Time Control
Hold Control