2.4 Condensate drainage system.
The condensate produced inside the boiler must be drained. Therefore the boiler is
provided with a condensate trap. The condensate trap fitting is to be connected to a 32
mm PVC condensate drainage system. It is recommendable to install a further water trap
on the condensate drainage system before the condensate reaches the sewer. Only
plastic tubes of the standard civil condensate drainage systems are suitable to drain the
condensate towards the sewer of the house.
2.5 Gas connections.
This appliance shall be installed only by authorised persons and in accordance with the
manufacturer's installation instructions, local gas fitting regulations, municipal building
codes, electrical wiring regulations, local water supply regulations, AS 5601-2004 - Gas
Installations and any other statutory regulations.
The boiler must be installed on a flat vertical wall which is capable of supporting the weight
of the boiler.
The location must take account of the flueing method to be used and the position of the
flue terminal, with regard to the requirements of AS5601.
Refer to AS5601 for gas pipe size details.
The 5.32 N-N3V boiler has been designed to operate on Natural Gas and Propane Gas.
The 5.24 N-N3V boiler has been designed to operate on Natural Gas.
Before performing the gas connection, all the ducts of the fuel system are to be cleaned
inside in order to remove possible residual substances which could cause malfunctioning.
The apparatus duct sections must ensure a sufficient gas supply to cover the maximum
request. For the same reason check the pressures of the gas which will be used.
2.6 Electrical connections control board functioning and regulation
The electrical safety of the equipment is reached only when correctly connected to an
efficient grounding system performed according to the electrical rules in force. The
fundamental security requirement must be checked.
Warning: we cannot be held responsible for damages to people, things or animals caused
by neglecting grounding system and the above mentioned rules.
All the boiler connections are absolutely not fit as grounding. This has to be verified before
performing the boiler electrical connection.
The use of any component run by electrical power involves the strict observance of certain
fundamental rules, such as:
Do not touch the boiler with parts of the body which are wet and/or damp and/or bare;
Do not pull the wiring;
Do not leave the boiler exposed to the rain, the sun, etc., unless explicitly requested;
Children and not professionally qualified persons are not allowed to use the apparatus.