Specifications
15. Setting the limits manually:
1. Press and hold the black button until the yellow indicator light starts flashing slowly then release.
2. Adjust the position of the door by using the black and orange buttons. Black moves the door UP (open) and orange
moves the door DOWN (close).
Check to be sure the door opens high enough for your vehicle.
3. Push the remote control or door control. This sets the UP (open) limit and begins closing the door.
Immediately press either the orange or the black button. The door will stop.
Adjust the desired DOWN (close) limit position using the black and orange buttons. Check to be sure the door is fully
closed without applying excessive pressure on the rail (rail should not bow upwards and the chain/belt should not sag or droop
below the rail). Push the remote control or door control. This sets the DOWN (close) limit and begins opening the door.
NOTE: If neither the black or the orange button is pressed, the door will reverse off the floor and the DOWN travel limit will be
set automatically.
4. Open and close the door with the remote control or door control 2 or 3 times.
• If the door does not stop in the desired UP (open) position or reverses before the door stops at the DOWN (close) position,
repeat Setting the Limits and Force, see adjustment steps 26 and 27.
• If the door stops in both the desired UP (open) and DOWN (close) positions, proceed to Test the Safety Reversal System.
Input Voltage ....... 230-240 VAC, 50Hz
Max. Pull Force ... 600N (MT600), 1000N (MT1000)
Power .................. 6Nm (MT600), 10Nm (MT1000)
Watts.................... 130M (MT600), 190W (MT1000)
Standby Power .... 5.5W (MT600), 6.5W (MT1000)
Motor
Type..................... DC gearmotor permanent
lubrication
Drive Mechanism
Drive .................... Chain/belt with two-piece trolley on
steel rail.
Length of Travel... Adjustable to 2,3m (7-1/2 feet)
Travel Rate .......... 5"-7" (127-178mm) per second
Lamp.................... On when door starts, off 2-1/2
minutes after stop.
Door Linkage ....... Adjustable door arm. Pull cord
trolley release.
Safety
Personal .............. Push button and automatic stop in
down direction. Push button and
automatic stop in up direction.
Electronic............. Automatic force adjustment
Electrical .............. Transformer overload protector and
low voltage push button wiring.
Limit Device......... Optical RPM/Passpoint detector.
Limit Adjustment .. Electronic, Semi and Fully
Automatic.
Start Circuit.......... Low voltage push button circuit.
Dimensions
Length (Overall)... 3,2m (122-1/2")
Headroom Required 30mm
Hanging Weight... 14,5 kg (32 lb)
Receiver
Memory Registers 16 (MT600), 64 (MT1000)
Operating Frequency 433.92MHz
SPECIAL NOTE: Merlin strongly recommends that the
protector system be installed on all garage door openers.
Your opener can be activated by any of the following devices:
• The Lighted Door Control Button. Hold the button down
until door starts to move.
• The Outside Keylock or Keyless Entry System (if you
have installed either of these accessories).
• The Remote Control Transmitter. Hold the push button
down until the door starts to move.
Opening the Door Manually: Door should be fully closed
if possible. Weak or broken springs could allow an open
door to fall rapidly. Property damage or serious personal
injury could result.
The door can be opened manually by pulling the release
handle down. To reconnect the door, pull the release handle
down and toward the opener.
Do not use the manual release handle to pull the door
opener or closed. When the Opener is Activated by
Remote Control or Lighted Door Control Button:
1. If open, the door will close. If closed, the door will open.
2. If closing, the door will stop.
3. If opening, the door will stop (allowing space for entry and
exit of pets and for fresh air).
4. If the door has been stopped in a partially open or closed
position, it will reverse direction.
5. If an obstruction is encountered while closing, the door will
reverse.
6. If an obstruction is encountered while opening, the door will
reverse and stop.
7. The optional Protector System™ uses an invisible beam
which, when broken by an obstruction, causes a closing
door to open and prevents an open door from closing. It is
STRONGLY RECOMMENDED for homeowners with young
children.
Allow a 15 minute cooling period after 5 continuous
operations of the opener. The opener light will turn on: 1.
when opener is initially plugged in; 2. when the power is
briefly interrupted; 3. when the opener is activated.
The light turns off automatically after 2-1/2 minutes. Bulb size
is 230V/40W maximum.
OPERATION OF YOUR OPENER
17