Specifications

Position the Opener
NOTE: A 25mm (1") board (1) is convenient for setting an
ideal door-to-rail distance (unless headroom is not sufficient).
Raise the opener onto a stepladder. Open garage door. Place
a 25mm (1") board (1) laid flat on the top section of door near
the centerline as shown. Rest the rail on the board.
If the raised door hits the trolley, pull down on the trolley
release arm to disconnect the inner and outer trolley sections.
The trolley can remain disconnected until connecting door arm
to trolley is completed.
1
15
Hang the Opener
The opener must be securely fastened to a structural
support of the garage.
Three representative installations are shown. Yours may be
different. Hanging brackets (1) should be angled (Figure A) to
provide rigid support. On finished ceilings, (Figure B) attach a
sturdy metal bracket (not supplied) (4) to a structural support
before installing the opener. For concrete ceiling mount,
(Figure C), use concrete anchors provided.
On each side of opener measure the distance from the
opener to the structural support (or ceiling).
Cut both pieces of the hanging bracket to required lengths.
Flatten one end of each bracket and bend or twist to fit the
fastening angles. Do not bend at the bracket holes. Drill
4,5mm (3/16") pilot holes in the structural supports (or ceiling).
Attach brackets to supports with wood screws (2).
Lift opener and fasten to hanging brackets with screw, lock
washer and nut (3). Check to make sure rail is centered over
the door. REMOVE 25mm (1") board. Operate door manually.
If door hits the rail, raise header bracket. Use rail grease and
lubricate bottom surface of rail (5).
A
2
1
1
3
4
2
3
4
2
3
3
C
B
4
2
1
3
5
16
Attach Emergency Release Rope & Handle
Thread one end of rope (1) through hole in top of red handle so "NOTICE" reads
right side up as shown (3). Secure with an overhand knot (2). Knot should be at
least 25mm (1") from end of the rope to prevent slipping.
Thread other end of rope through hole in release arm of the outer trolley (4).
Adjust rope length so that handle is 1,8m (6 feet) above the floor. Secure with an
overhand knot.
NOTE: If it is necessary to cut rope, heat seal cut end with a match or lighter to
prevent fraying.
2
3
4
NOTICE
2
1
17
Connect Electric Power
TO AVOID INSTALLATION DIFFICULTIES, DO NOT RUN THE GARAGE DOOR OPENER UNTIL INSTRUCTED TO DO SO.
Connect the door opener only to an outlet controlled by a double pole switch.
4
2
4
5
5
1
3
IInnssttaallll tthhee LLiigghhtt aanndd LLeennss
Install a 40 watt maximum (230V, E27) light bulb in the socket
(1). Hinge the bottom of the lens (2) onto the cover from left of
the hinge bars (3) as shown. Close the lens by gently
squeezing the upper corners and inserting the tabs (4) into
slots on the cover (5).
To change bulb, squeeze the upper corners of the lens to
disengage tabs. The lens will drop open, remaining hinged at
bottom.
The light will turn on and remain lit for 2-1/2 minutes when
power is connected. After 2-1/2 minutes it will turn off.
18
6