Parts required:
1. Pt. No. 30Z1177 20A littlefuse FLM020 x1
2. Pt. No. 30Z1178 30A fuse holder (FLM Series) x1
3. Pt. No. 31Z2092 Label - 20A FLM fuse x1
4. Pt. No. 31Z2030 Label - 10A fuse x1
5. Pt. No. 31Z3061 No.6x3/8” self tap pan x1
PROCEDURE FOR REPLACING 13A ANTI-SURGE FUSES WITH 30Z1177 FLM020 Type
Brief description: The change in fuse is due to the manufacturer ceasing to make the 13A anti-surge
fuses Pt. No. 30Z0168 which are unique to our requirements. To overcome this we need to use the
FLM020 fuses Pt. No. 30Z1177 for the Microwave circuit on all Microcook HD1725 & HD1925 ovens.
The operation listed below is to be followed to any service calls where the 13A A/S fuses have blown.
1. Isolate oven from mains power
supply.
2. Remove rear cover to obtain
access to the side of the oven.
3. Strip back the GSS sleeving over the mains cable approx. 50mm and cable tie back into location.
(A)
4. Strip back the jacket of the mains cable, again approx. 50mm. (B)
A B
APPENDIX 5: Fitting 30Z1177 20A Anti surge fuse