User manual

V5151-581-00 12/11
Complete the electronic switch insert with corre-
sponding modules (see function overview).
PlusLink Expander (Art. no. MEG5130-0000)
¼
DANGER
Risk of death from electric shock.
All work on the device should only be carried out
by trained and skilled electricians. Observe the
country-specific regulations.
¼
DANGER
Risk of death from electric shock.
The outputs may carry an electrical current even
when the device is switched off. Always discon-
nect the fuse in the incoming circuit from the sup-
ply before working on connected loads.
¼
DANGER
Risk of death from electric shock.
The PlusLink carries an electrical current even
when the device is switched off. Before working
on the device, always disconnect it from the sup-
ply by means of the fuse in the incoming circuit. If
one or more PlusLink lines are separately fused in
your installation then they are not electrically iso-
lated from one another. In this case, you should
use the PlusLink Expander.
½
CAUTION
The device can become damaged.
The voltage differential between different phases
can damage the device. All devices connected to
one or more PlusLink lines must be connected to
the same phase.
Electronic switch insert
Operating instructions
Electronic switch insert
Art. no. MEG5151-0000
Electronic switch insert, 2-gang
Art. no. MEG5152-0000
Necessary accessories
Accessories
For your safety
ende
You can use the electronic switch insert (referred to be-
low as the insert) to switch ohmic, inductive or capaci-
tive loads per channel.
The insert is overload-proof and short-circuit-proof.
The insert also comes with one (1-gang insert) or two (2-
gang insert) PlusLink inserts, with which you can control
the channels from another location. The insert, complet-
ed with a module (see the function overview), is the re-
ceiving device and is controlled via PlusLink (PL) by the
sending device.
Sending devices are, for instance:
Central unit insert (completed with corresponding
modules)
Side controller Plus, 1-gang/2-gang
Mechanical push-buttons
External sensors
To be able to use the PlusLink, you require a separate
core in your installation.
|
The total length of cable sections in a PL line is
not allowed to exceed 100 m (when a 3-core ca-
ble is used).
½
CAUTION
The insert can become damaged!
Always operate the insert in compliance with
the specified technical data.
Observe the different minimum loads.
Connected devices can be damaged if you
connect mixed loads (inductive and capacitive)
on one channel at the same time.
Operate the insert only on a sinusoidal mains
voltage.
Switching socket-outlets is prohibited. The risk
of overloading and the risk of unsuitable loads
being connected is too high.
If a terminal is used for looping, the insert must
be protected with a 6 A circuit breaker.
Getting to know the electronic switch
insert
incandescent lamps
(ohmic load)
230 V halogen lamps
(ohmic load)
Low-voltage halogen lamps with
dimmable wound transformer
(inductive load)
Low-voltage halogen lamps with
electric transformer
(capacitive load)
Energy-saving lamps e.g.:
Osram Dulux Intelligent dim-
mable
Philips Master LED bulb dim-
mable
Function overview of the 1-gang insert
completed with corresponding modules
Module: Function:
Push-button module Basic,
1-gang
switching on/off
Push-button module Basic,
2-gang
switching on/off
retrieving and saving
light scenes
Push-button module Com-
fort, 1-gang
switching on/off
staircase lighting func-
tion
Push-button module Com-
fort, 2-gang
switching on/off
retrieving and saving
light scenes
staircase lighting func-
tion
Push-button module Com-
fort Plus with IR, 1-gang
switching on/off
staircase lighting func-
tion
24-hour time switch
week time switch
random function
IR function
Push-button module Com-
fort Plus, 2-gang
switching on/off
retrieving and saving
light scenes
staircase lighting func-
tion
24-hour time switch
week time switch
random function
CONNECT RF push-but-
ton module, 1-gang
switching on/off
switching CONNECT
devices
CONNECT RF push-but-
ton module, 2-gang
switching on/off
switching CONNECT
devices
Rotary module switching on/off
retrieving and saving
light scenes
ARGUS 180 flush-mount-
ed sensor module
brightness dependent
staircase lighting func-
tion
ARGUS 180 flush-mount-
ed sensor module with
switch
brightness dependent
staircase lighting func-
tion
permanently switching
staircase lighting on/off
ARGUS Presence 180/
2.20 m flush-mounted sen-
sor module
brightness dependent
staircase lighting func-
tion
ARGUS Presence sensor
module with IR
brightness dependent
staircase lighting func-
tion
IR function
Display timer module switching on/off
receiving "DCF time"
Display thermostat module Solutions
(see module manual)
Function overview of the 2-gang-insert
completed with corresponding modules
Module: Function:
Push-button module Basic,
1-gang
switching both channels
on/off together
Push-button module Basic,
2-gang
switching both channels
on/off separately
Push-button module Com-
fort, 1-gang
switching both channels
on/off together
staircase lighting func-
tion
Push-button module Com-
fort, 2-gang
switching both channels
on/off separately
staircase lighting func-
tion
Push-button module Com-
fort Plus with IR, 1-gang
switching both channels
on/off together
staircase lighting func-
tion
24-hour time switch
week time switch
random function
IR function
Push-button module Com-
fort Plus, 2-gang
switching both channels
on/off separately
staircase lighting func-
tion
24-hour time switch
week time switch
random function
CONNECT RF push-but-
ton module, 1-gang
switching on/off
switching CONNECT
devices
CONNECT RF push-but-
ton module, 2-gang
switching both channels
on/off separately
switching CONNECT
devices
Rotary module switching on/off
ARGUS 180 flush-mount-
ed sensor module
brightness dependent
staircase lighting func-
tion
brightness independent
staircase lighting func-
tion
ARGUS 180 flush-mount-
ed sensor module with
switch
brightness dependent
staircase lighting func-
tion
brightness independent
staircase lighting func-
tion
permanently switching
staircase lighting on/off
ARGUS Presence 180/
2.20 m flush-mounted sen-
sor module
brightness dependent
staircase lighting func-
tion
brightness independent
staircase lighting func-
tion
ARGUS Presence sensor
module with IR
brightness dependent
staircase lighting func-
tion
brightness independent
staircase lighting func-
tion
IR function
Display timer module switching on/off
receiving "DCF time"
|
If you do not install the device in a single, standard
flush mounting box, the maximum permissible
load is reduced due to the restricted heat dissipa-
tion:
* If several factors apply, add the load reductions togeth-
er.
Wiring the insert (1-gang) for the de-
sired application
Insert as stand-alone device
Two inserts connected in parallel
Insert with mechanical push-button via PlusLink
A Electronic switch insert
B Mechanical push-button (toggle mode)
Installing the insert
Load reduced
by
when installed
25 %
in hollow walls *
Several installed together in combi-
nation *
30 % in 1-gang or 2-gang surface-mount-
ed housing
50 % in 3-gang surface-mounted housing
PL
L
L
N
OR
PL
L
L
N
PL
L
PL
L
L
N
B
A
Insert in combination with sending device via
PlusLink
(here shown with side controller Plus)
A Electronic switch insert
B Side controller Plus 1-gang / 2-gang (sending de-
vice)
Insert in combination with external sensor via
PlusLink
(here shown with brightness sensor with wind sen-
sor interface)
A Electronic switch insert
B Brightness sensor with wind sensor interface
Wiring the insert (2-gang) for the de-
sired application
|
If you connect loads on only one channel on a 2-
gang insert, then it must be channel 1.
Insert as stand-alone device
PL
L
PL
L
PL
L
PL
L
N
B
A
max. 10
PL
L
PL
L
PL
L
N
max. 10
B
A
PL2
PL1
2
1
L
L
N
OR
OR