User manual
V5170-581-00 12/11
System M
System Design
– Complete the universal dimmer for CFLs / LED lamps
with:
• corresponding 2-gang rockers in design System M or
System Design.
• frames in design System M or System Design.
¼
DANGER
Risk of death from electric shock.
All work on the device should only be carried out
by trained and skilled electricians. Observe the
country-specific regulations.
¼
DANGER
Risk of death from electric shock.
The outputs may carry an electrical current even
when the device is switched off. Always discon-
nect the fuse in the incoming circuit from the sup-
ply before working on connected loads.
Universal dimmer for CFLs / LED lamps
Operating instructions
Universal dimmer for CFLs / LED
lamps
Art. no. MEG5170-0300
Universal dimmer for CFLs / LED
lamps
Art. no. MEG5170-4000
Necessary accessories
For your safety
ende
You can use the universal dimmer for CFLs / LED lamps
(referred to below as the device) to switch and dim ohm-
ic, inductive or capacitive loads:
The device automatically recognises the connected
load. The device is overload-proof, short-circuit-proof
and has a soft start function.
The device has two scene buttons for retrieving, chang-
ing and saving two scenes.
When energy-saving lamps are connected, additional
possible settings are activated. You can set the dimming
range, switch off the start function and switch the operat-
ing mode (from trailing edge phase control to leading
edge phase control, recommended for Osram).
½
CAUTION
The device can become damaged!
• Always operate the device in compliance with
the specified technical data.
• Operate the device with a minimum load of
10 VA.
• Connected devices can become damaged if
you connect mixed loads (inductive and capac-
itive) at the same time.
• When energy-saving lamps are used: Only
connect energy-saving lamps from the same
manufacturer.
• The device is designed for sinusoidal mains
voltage.
• When transformers are used: Only connect
dimmable transformers to the dimmer.
• Dimming socket-outlets is prohibited. The risk
of overloading and the risk of unsuitable devic-
es being connected is too high.
• If a terminal is used for looping, the device must
be protected with a 6 A circuit breaker.
Getting to know the universal dimmer
incandescent lamps
(ohmic load)
230 V halogen lamps
(ohmic load)
Low-voltage halogen lamps with
dimmable wound transformer
(inductive load)
Low-voltage halogen lamps with
electric transformer
(capacitive load)
Dimmable energy-saving
lamps:
• Osram
• Philips
• Govena
• Megaman
Dimmable LED lamps:
• Osram
• Philips
• Ledon
• Toshiba
|
Connect at most three dimmers to one cable with
16 A fuse protection!
|
If you do not install the device in a single, standard
flush mounting box, the maximum permissible
load is reduced due to the restricted heat dissipa-
tion:
* If several factors apply, add the load reductions togeth-
er.
Wiring the insert
Installing the device
Installing the device
Load reduced
by
when installed
25 %
in hollow walls *
Several installed together in combi-
nation *
30 % in 1-gang or 2-gang surface-mount-
ed housing
50 % in 3-gang surface-mounted housing
L
L
N
OR
|
The following functions are only available when
energy-saving lamps are connected.
Dimming range
In order to be able to dim energy-saving lamps from dif-
ferent manufacturers without faults, the dimming range
has been restricted. However, you can adjust the dim-
ming range to your energy-saving lamp.
Setting the dimming range
|
When setting the dimming range, problems may
occur (see chapter "What should I do if there is a
problem?")
1 Call up setting mode (the lamps are briefly switched
off and on)
2 Set max. brightness value
3 Temporarily save max. brightness value
4 Set min. brightness value
5 Temporarily save min. brightness value
6 Save values permanently and exit setting mode (the
lamps are briefly switched off and on)
Start function
Most energy-saving lamps need time to warm up when
switched on. The start function is therefore activated au-
tomatically when an energy-saving lamp is connected.
The energy-saving lamp is operated at maximum bright-
ness for approx. 2 s when switched on and then dims au-
tomatically to the desired brightness.
Switching off the start function
This can be switched off for energy-saving lamps which
do not require a start function.
Seting the device
>
3 s
>
3 s
>
3 s
23
45
1 / 6
10x
Operating mode
When connecting energy-saving lamps, "trailing edge
phase control" operating mode is automatically activat-
ed.
Changing operating mode
For certain energy-saving lamps, e.g. Osram, you have
to switch to "leading edge phase control" operating
mode.
Switching load on/off
Dimming load
Retrieving light scenes
Standard scenes
All devices are delivered from the factory with preset-
tings for a light scene.
Changing and saving light scenes
1 Set the brightness value.
2 Save scene: press the S1 or S2 push-button for a
long time.
Resetting to default settings
Operating the device
S1: light on (100%)
S2: light off
Operation Status feedback
Lamps switch off and
back on twice within
10 s.
6x
<
0,5 s
>
0,5 s
< 0,5 s
>
3 s
1
2
10 s
The device regularly dims down during operation
and cannot be dimmed up.
• Allow the device to cool down and reduce the con-
nected load.
The load cannot be switched back on.
• Allow the device to cool down and reduce the con-
nected load.
• Rectify any possible short circuits.
• Renew defective loads.
LV halogen lamps are not switched on with soft
start.
Electronic transformers are detected as energy-saving
lamps.
• Make settings for energy-saving lamps (switch off the
start function, increase dimming range).
The load is dimmed to the minimum brightness.
The brightness has exceeded the maximum value for the
energy-saving lamp.
• Reduce the maximum brightness value (setting dim-
ming range).
The load flickers at min. brightness setting.
The brightness has not reached the minimum value for
the energy-saving lamp.
• Increase the minimum brightness value (setting dim-
ming range).
The load flickers continuously.
Incorrect operating mode (e.g. for Osram) set.
• Switch operating mode to leading edge phase control.
The load can only be dimmed slightly.
The dimming range is set too low.
• Increase the dimming range.
Merten GmbH, Fritz-Kotz-Str. 8, D-51674 Wiehl
www.merten.com
Service Center:
Technical support / InfoLine:
What should I do if there is a problem?
Technical data
Mains voltage: AC 220/230 V ∼, 50/60 Hz
Switching capacity: 10-200 VA
for energy-saving
lamps and leading
edge phase control: max. 40 VA
wound, dimmable
transformers: min. 40 VA
Neutral conductor: not required
Connecting terminals: Screw terminals for max. 2x
2.5 mm
2
or 2x 1.5 mm
2
Protection: 16 A circuit breaker
Features: • Short-circuit-proof
• overload-proof
• soft start
• automatic load detection