User Instructions Part 2

OPERATING INSTRUCTIONS  FOR OEM USE ONLY
© 2013 Mertik Maxitrol GmbH & Co. KG, All Rights Reserved.
25 / 28
1 2
ON
AM
PM
OFF
OFF: 
1.   Press 
 or   or   button to enter 
Manual mode.
2.   Press 
 button to enter Thermostatic 
mode.
3.  Press Random icon button to enter 
Random mode.
1 2
ON
AM
PM
OFF
PROGRAM Temperature SETTING: 
1.   Press 
 button and hold until  ,
 , Set temperature (Thermostatic) 
displayed.
2.  To continue press 
 button.  ,   
displayed,  temperature  fl ashes  and 
wait.
3.  To select OFF temperature press 
or 
 button.
4.  To confi rm press 
 button or wait.
NOTE: The  ON  (Thermostatic)  and  OFF  set  temperatures  are 
the same for each day.
1 2
ON
AM
PM
OFF
Time SETTING: 
1.   Press 
 button and hold until  ,  ,
 displayed, hour fl ashes.
2.  To select hour press 
 or   button.
3. To confi rm press 
 button.  ,
 dis-
played, minutes fl ash.
4.  To select minutes press 
 or   but-
ton.
1 2
ON
AM
PM
OFF
5. To confi rm press   button.  ,  ,
displayed, hour fl ashes.
6. To select hour, press 
 or   button.
7. To confi rm press 
 button.  ,  ,
displayed, minutes fl ash.
8.  To select minutes press 
 or   but-
ton.
NOTE: If you stop programming at this point, program 2 remains 
deactivated.
NOTE: Programs 1 and 2 use the same ON (Thermostatic) and 
OFF temperatures.
THERMOSTATIC MODE
1 2
ON
AM
PM
OFF
ON: 
Press 
 button. Thermostat icon dis-
played, preset temperature displayed 
briefl y, and then room temperature dis-
played.
OFF: 
1.   Press 
 button.
2.   Press 
 or   button to enter Manual 
mode.
3.   Press 
 button
to enter Countdown 
Timer mode.
    4.   Press 
 button to enter Random 
mode.
1 2
ON
AM
PM
OFF
SETTING: 
1.   Press 
 button and hold until Ther-
mostat icon displayed, temperature 
fl ashes.
2.  To adjust SET temperature press 
or 
 button.
3. To confi rm press 
 button or wait.
COUNTDOWN TIMER
1 2
ON
AM
PM
OFF
ON/SETTING: 
1.  Press and hold 
 button until hour-
glass icon displayed and hour fl ashes. 
2. To select hour press 
 or   button.
3. To  confi rm  press 
 button. Minutes 
fl ash.
4.   To select minutes press 
 or   but-
ton.
5. To confi rm press 
 button or wait.
OFF: 
 Press 
  button,  hourglass and count-
down time disappear.
NOTE: At end of countdown time period, the fi re turns OFF. The 
CountdownTimer only works in Manual, Thermostatic, and 
Random modes. Maximum countdown time is 9 hours.
PROGRAM MODE
NOTE:  The set temperature for Thermostatic Mode is the tem-
perature for the ON time in Program Mode. Changing 
the Thermostatic Mode set temperature also changes 
the ON time temperature in Program Mode.
1 2
ON
AM
PM
OFF
ON: 
Press 
 button.  ,   or
, ON or OFF 
displayed. 
10-SYMBOL