INSTALLATION AND OPERATING INSTRUCTIONS      DR AFT  FOR OEM USE ONLY
© 2019 Mertik Maxitrol GmbH & Co. KG, All Rights Reserved.
TOUCHPAD / WALL  SWITCH
Increase ame height
ON / OFF
Decrease ame height
Figure  19: Touchpad / Wall  Switch
AMBIENT TEMPERATURE RANGE
  CSA:  Wall  Switch / Touchpad:  176 °F
  CE:  Wall  Switch / Touchpad:  80 °C
To Turn ON Appliance 
▪ Press 
 button (see gure 19, page 11) until two short 
beeps (CE version) or continuous beeping (CSA version) con-
rm the start sequence has begun; release button.
▪ Once pilot ignition is conrmed, there is main gas ow.
If the pilot does not stay lit after several tries, turn the main 
valve knob to OFF and follow the instructions “TO TURN OFF 
GAS TO APPLIANCE” (see page 10).
Flame Height Adjustment
▪ Press and hold 
 (large ame) button to increase ame height.
▪ Press and hold 
 (small ame) button to decrease ame height 
or to set appliance at pilot ame.
Standby Mode (Pilot Flame)
▪ Press and hold 
 (small ame) button to set appliance at pilot ame.
To Turn OFF Appliance
If  the  appliance  will  not  operate,  follow  the  instructions “TO 
TURN OFF GAS TO APPLIANCE”
 (see page 10)
.
▪ Press   button.
TO OPEN AND CLOSE SOLENOID VALVE / BURNER 
▪ Simultaneously press the 
 and   (small ame) buttons 
to switch the decorative burner OFF.
▪ Simultaneously press 
 and   (large ame) buttons but-
tons to switch decorative burner on. 
NOTE:  The latching solenoid valve cannot operate manually. If 
the receiver battery runs down it will remain in the last 
operating position. 
SWITCH PANEL 
Figure 20: Switch Panel
A)  Increase ame height
B) ON / OFF
C)  Decrease ame height
AMBIENT TEMPERATURE RANGE
  CSA:  Switch Panel: 221 °F
  CE:  Switch Panel: 105 °C
To Turn ON Appliance 
▪ Press “B” button (see gure 20, page 11) until two short beeps 
(CE version) or continuous beeping (CSA version) conrm the 
start sequence has begun; release button.
▪ Once pilot ignition is conrmed, there is main gas ow.
If the pilot does not stay lit after several tries, turn the main 
valve knob to OFF and follow the instructions “TO TURN OFF 
GAS TO APPLIANCE” (see page 10).
Flame Height Adjustment
▪ Press and hold “A” button to increase ame height.
▪ Press and hold  “C”  button to decrease  ame height or to  set 
appliance at pilot ame.
Standby Mode (Pilot Flame)
▪ Press and hold “C” button to set appliance at pilot ame.
To Turn OFF Appliance
If  the  appliance  will  not  operate,  follow  the  instructions “TO 
TURN OFF GAS TO APPLIANCE”
 (see page 10)
.
▪ Press “B” button.
TO OPEN AND CLOSE SOLENOID VALVE / BURNER 
▪ Simultaneously press the “B” and “C” buttons to switch the dec-
orative burner OFF.
▪ Simultaneously  press  “B”  and  “A”  buttons  buttons  to  switch 
decorative burner on. 
NOTE:  The latching solenoid valve cannot operate manually. If 
the receiver battery runs down it will remain in the last 
operating position. 