Users Manual Part 1

12 / 30
INSTALLATION AND OPERATING INSTRUCTIONS DRAFT FOR OEM USE ONLY
© 2019 Mertik Maxitrol GmbH & Co. KG, All Rights Reserved.
Handset One Button and Two Button Ignition
Change from one button (default setting) to two button ignition or
vice versa by pressing and holding
button for 10 sec. imme-
diately after installing batteries.
is displayed and or
(One
or Two Button Ignition
) is ashing. When change is complete
changes to
or vice versa.
Deactivate Functions
1. Install batteries. All icons are displayed and ashing.
2. While the icons are ashing, press the relevant function button
and hold for 10 sec.
3. The function icon will ash until deactivation is complete. De-
activation is complete when the function icon and two horizon-
tal bars are displayed.
NOTE: If a deactivated button is pressed, there is no function,
and two horizontal bars are displayed.
NOTE: Deactivation remains in effect after change of batteries.
Activate Functions
1. Install batteries. All icons are displayed and ashing.
2. To activate a function, press the relevant button and hold for
10 sec.
3. The function icon will continue to ash until activation is com-
plete. Activation is complete when the function icon is dis-
played.
The following Functions can be Deactivated / Activated
CHILD PROOF
PROGRAM MODE
THERMOSTATIC MODE (also deactivates PROGRAM MODE)
ECO MODE
LIGHT / DIMMER OPERATION
▪ CIRCULATING FAN OPERATION
2ND BURNER FEATURE
▪ COUNTDOWN TIMER
TECHNICAL DATA
AMBIENT TEMPERATURE RANGE
CSA: Handset: 32 °F to 131 °F
CE: Handset: 0 °C to 55 °C
RADIO FREQUENCY
CSA: 918.0 MHz for U.S. (FCC), Canada (ISED), New Zea-
land (RNZ) and Australia (ACMA) (handset, receiver)
CE: 868.1 MHz for Europe (handset, receiver)
(see general radio frequency information on page 4.)
RADIATED POWER OUTPUT
CSA: 90.8 µV/m
CE: -3.5 dBm
POWER SUPPLY
Handset: 2 x 1.5 V “AAA” (quality alkaline recommended)
NOTICE
Wiring of valve and receiver must be completed before starting
ignition. Failure to do so could damage the electronics.
NOTICE
The handsets and receivers are not interchangeable with previ-
ous electronics G6R and B6R-R8(9)U(T).
To avoid damaging the electronics, do NOT use metal tools to
remove the batteries from the handset / receiver.
Without using a mains adapter, battery replacement is recom-
mended at the beginning of each heating season.
Old or dead batteries should be removed immediately. If left
in the unit the batteries can overheat, leak, and / or explode.
Do NOT expose batteries (including during storage) to direct
sunlight, excessive heat, re, moisture, or severe impact. Each
of these conditions can cause the batteries to overheat, leak,
and / or explode.
Batteries must be kept within their recommended temperature
limits (ambient battery temperature range: 32 °F to 131 °F /
0 °C to 55 °C).
New and old batteries and different brands of batteries should
not be used together. Mixing of various batteries can cause
the batteries to overheat, leak, and / or explode.
SYNCHRONIZATION RECEIVER / SYMAX HANDSET
NOTICE
See page 7 for more information about synchronization between
receiver and Symax.
GENERAL NOTES
Batteries – Handset
Low battery indicator on Symax.
SYMAX HANDSET
Program Mode
Countdown Timer