User's Manual
Table Of Contents
- Contents
- List of Figures
- List of Tables
- About This Guide
- About Meru Access Points
- Installing the AP100
- Installing the AP200
- Specifications
- Declarations of Conformity and Regulatory Information
- Translated Safety Warnings
- Channels
Installing the Access Point
Installing the AP200 23
Mounting the Access Point
You can mount an AP200 in the following ways:
z Horizontally, as described in the “Horizontal Mounting” section.
z Vertically, as described in the “Vertical Mounting” section.
z Below a hanging ceiling, as described in the “Mounting Below a Suspended Ceiling” section.
z Above a tiled hanging ceiling, as described in the “Mounting Above a Suspended Ceiling”
section.
Horizontal Mounting
To horizontally mount an AP200:
1. Place the AP200 flat on the horizontal surface.
2. For each antenna, loosen the knurled ring at the base of the antenna (see Figure 13), point the
antenna straight up, then retighten the ring.
Figure 13: AP200 Antenna Connection
3. Connect the PoE 100BaseT Ethernet cable to the 100/1000 Ethernet connector, shown in
Figure 14.
Caution!
When changing the orientation of the antennas, be sure to slightly loosen the knurled ring
before moving the antenna. Retighten the ring afterward. Otherwise, you might damage the internal
cabling in the AP.
Turn clockwise
to tighten
A
ntenna
Access Point 200
ETHERNET
3.3 VDC
ANT 2
00110
Caution!
Be sure to connect the Ethernet cable to the Ethernet port; the cable can mistakenly be
plugged into the Console port.