Installation Guide

Table Of Contents
Installing AP320i
© 2012 Meru Networks, Inc. Installing AP320i 39
4. Connect one end of the CAT5 (or greater) Ethernet cable to the 100/1000 Ethernet connector.
Figure 16: AP320i Ethernet Port on the Right
5. Optionally install a small lock (not supplied) to secure the AP320i to the ceiling rail. See Figure 17.
To do this, you need the security key that shipped with the AP320i.
Figure 17: Optionally Install Your Own Lock on AP320i
Mount AP320i Above a Suspended Ceiling
Caution!
Be sure to connect the Ethernet cable to the Ethernet port. The cable can
mistakenly be plugged into the Console port; if you do this, the AP won’t power up.
Note:
AP320i is not plenum-rated and should only be mounted above ceilings in
non-plenum air space, such as a return airflow for air conditioning.
g00240
LAN 5V DCCON
console Ethernet
T-bar
(in ceiling)
Mounting bracket
AP300i
Security
clip
Lock security clip.Security clip fully inserted.
Insert security clip.
00236