User's Manual

Table Of Contents
Air Handling Space Requirements56
Meru Networks recommends that customers use only a DAS that has been tested to work with
Meru hardware and software. Meru does not provide any site surveys, design or implementa-
tion of Wi-Fi over DAS. Meru recommends that customers obtain such services from a trained
and qualified systems integrator or from their DAS vendor.
Air Handling Space Requirements
When installing APs in an air-handling space, as described in Article 300.22(C) of the National
Electric Code® (2008 edition, pages 70-135 and 70-136), the unit should only be powered by
the Ethernet port (PoE), not by the AC-powered power supply.
Only AP822eV2 with plastic façade removed can be applied in air-handling space.
When the product is installed in air-handling spaces, the cables employed should be suitable
under NEC Articles 300.22 and 725 and marked accordingly, for use in plenums and air-han-
dling spaces with regard to smoke propagation, such as CL2-P, CL3-P, MPP or CMP.
The products should be installed in accordance with all applicable, local regulations and prac-
tices. Compliance applies only when the plastic facade is removed from the AP.
Frequencies Blocked for Regulatory
Compliance
These products are for indoor use only, in U-NII-1 and/or U-NII-3 band when Dynamic Fre-
quency Selection, DFS, from 5.25-5.35 GHz and 5.47-5.725 GHz, is disabled. With DFS
approval, these products can operate in U-NII-2 or U-NII-2e. To ensure compliance with local
regulations, be sure to set your Access Point to the country in which you are using the Access
Point.
Underwriters Laboratories
Use only listed e information technology equipment (ITE) I.T.E. equipment.
The unit is intended for installation in Environment A as defined in IEEE 802.3.af.All intercon-
nected equipments must be contained within the same building, including the interconnected
equipment's associated LAN connection.
Suitable for use in environmental air space in accordance with Section 300-22(c) of the
National Electrical Code, and Sections 2-128, 12-010(3) and 12-100 of the Canadian Electri-
cal Code, Part 1, C22.1.