Specifications

Source Organization
USI CVS2/RD2/NS
DOC NO.:
Original Effective Date
01-09-2014
AP832e / AP832i /AP822e /AP822i
Hardware
Specification
PAGE
9 OF 10
Operating humidity: 5 to 95 percent (non-condensing)
Non-operating (storage) temperature: -40 to +70°C
Non-operating (storage) humidity: 5 to 95 percent (non-condensing)
3.3.18 Reliability Requirements
MTBF must be at least 43,800 hours at 50C for the AP calculated using the Telcordia
SR-332 method and provide MTBF at 25C, too.
4 Regulatory Compliance Requirements
4.1.1 Ethernet Standards
Ethernet IEEE 802.3
Power Over Ethernet IEEE 802.3at
Wireless IEEE 802.11a/b/g /n/ac
4.1.2 Safety
UL 60950-1, 2nd Edition, 2007-03-27
CSA C22.2 No. 60950-1-07, 2nd Edition, 2007-03
EN 60950-1:2006+A12:2011
IEC 60950-1:2005 Second Edition
4.1.3 Unintentional radiation Standard
FCC Part 15.107 - 47CFR15.107 October 1, 2008 Class B
FCC Part 15.109 - 47CFR15.109 October 1, 2008 Class B
ICES-003 Class B – issue 4, February 2004
EN 301 489-1
EN 301 489-17
EN55022 Class B – 2006
EN55024 / AS/NZS CISPR 24 / Immunity
EN61000-4-2 Electrostatic Discharge (ESD): Performance Criterion B.
EN61000-4-3 Radiated Electromagnetic Fields (RS): Performance Criterion A.
EN61000-4-4 Electrical Fast Transient / Burst (EFT): Performance Criterion B.
EN61000-4-5 Lightning Surge Attachment: Performance Criterion B.
EN61000-4-6 Conducted Radio Frequency Disturbances (CS): Performance Criterion
A.
Japan VCCI Class B
4.1.4 intentional radiation Standard
FCC Part 15.247 - 47 CFR Ch. I (10–1–00 Edition) (2400 – 2483.5 MHz and 5725 -