Technical data

© 2012 Meru Networks, Inc. Alarms 323
17.
Acct Radius server
switchover failed
major
all controller
models
An attempted switchover from one
Accounting Radius Server to the other
server failed.When this message occurs,
the Primary Accounting Radius server is
configured but not reachable and the
Secondary Accounting Radius server is
not configured.
This message is generated only for
802.1x switchover failure, not for Captive
Portal switchover fail lure.
An example looks like this:
Accounting Radius Server Switch Major
06/07/2010 14:22:26 Primary Accounting
Radius Server <172.18.1.7> failed. No
valid Secondary Accounting Radius
Server present. Switchover FAILED for
Profile <wpa>
18.
Master down critical
all controller
models
N+1 Master controller is down and no
longer in control; the slave controller will
now take over.
19.
Master up critical
all controller
models
N+1 Master controller is up and running;
this controller will now take control away
from the slave controller.
20.
CAC limit reached major
all controller
models
Admission control in ATM networks is
known as Connection Admission Control
(CAC) - this process determines which
traffic is admitted into a network. If this
message occurs, the maximum amount of
traffic is now occurring on the network
and no more can be added.
21.
N-Upgrade License
checkout failed
major
AP301,
AP302, AP311
An 11N license is not available to support
11n mode for the specified AP300. You
can either obtain an N license or
reconfigure the AP to ABG mode. See the
System Director Release Notes for
directions.
No. Alarm Severity Source Explanation