Orient the AP433e horizontally so that you can read the Meru logo and
the Console and network ports are pointed downwards - this orientation
provides optimum MIMO performance.
Align the mounting screws on the back of the AP433e with the
corresponding holes on the mounting bracket.
Slide the AP433e downwards until the screws click into the holes. They
should seat fairly firmly.
Slide the mounting bracket’s locking bar to the right, locking the AP in
place.
If desired, use the provided clip to lock the bracket shut by sliding it
through the aligned holes on the right-hand side of the bracket.
Attach the antennas to the AP.
Connect one end of the Ethernet cable to the switch and the other end to
the AP433e Ethernet port. See Figure 9, IO Port of AP433e
Figure 9, IO Port of AP433e
Caution!
Be sure to connect the Ethernet cable to the Ethernet port; the cable can
mistakenly be plugged into the Console port. If you do this, the AP won’t power up.