4.7.6 Mount AP433e on an Interlude T-Bar
The mounting procedure for a ceiling that has interlude T-Bar supports is similar to
that of mounting on a suspended ceiling. However, this procedure requires a
specialized mounting bracket, as depicted in Figure 14, T-Bar Mounting Adapter
(MNT-SCRMKIT-04)
Figure 14, T-Bar Mounting Adapter (MNT-SCRMKIT-04)
Remove the ceiling tile alongside which the AP will be mounted.
Be sure that AP433e is not locked by inserting the locking key into the
Unlock mechanism as shown in Figure 15, Unlock
Figure 15, Unlock
Align the mounting bracket with the AP433e slots used for the ceiling t-
bar in Mount AP433e below a Suspended Ceiling.
Press down on the tab indicated on the underside of the AP and twist the
AP into place.
Push down on the thumbscrews provided on the mounting bracket and
clip it to the ceiling bar that will support the AP.
Tighten the screws to ensure that the mechanism stays locked in place.
Connect one end of the CAT5 (or greater) Ethernet cable with PoE to the
Ethernet connector shown in Figure 15, Unlock above
Caution!
Be sure to connect the Ethernet cable to the Ethernet port. The cable can
mistakenly be plugged into the Console port; if you do this, the AP won’t power up.