Operating Guide
12
English
Push Lever
Nose
At Firing
Push
Lever
Nose
Workpiece
This tool is equipped with a lockout feature that prevents
the tool from being activated when there are 4 or less nails
in the magazine.
Before actually beginning the nailing work, test the Nailer
by using the checklist below. Conduct the tests in the
following order.
If abnormal operation occurs, stop using the Nailer and
contact a Hitachi authorized service center immediately.
(1) DISCONNECT AIR HOSE FROM NAILER.
REMOVE ALL NAILS FROM NAILER.
□
ALL SCREWS MUST BE TIGHTENED.
If any screws are loose, tighten them.
□
THE PUSH LEVER AND TRIGGER MUST MOVE
SMOOTHLY WITH PULLING BACK THE NAIL
FEEDER.
Nail Feeder
Push Lever
Do not connect
air hose
(2) Adjust the air pressure to 70 psi (4.9 bar 5 kgf/cm
2
).
Connect the air hose.
Do not load any nails in the Nailer.
□
THE NAILER MUST NOT LEAK AIR.
Hold the Nailer downward and pull the trigger with
pulling back the nail feeder.
□
THE NAILER MUST NOT DRIVE.
Nail Feeder
Pull Trigger
(3) With fi nger off the trigger, depress the push lever
against the workpiece.
□
THE NAILER MUST NOT DRIVE.
Do not pull Trigger
Depress Push Lever
(4) Without touching the trigger, fi rst depress the push
lever against the workpiece.
Pull the trigger with pulling back the nail feeder.
□
THE NAILER MUST DRIVE.
000Book_NR38AK_US.indb 12000Book_NR38AK_US.indb 12 2014/12/03 15:12:412014/12/03 15:12:41