Operation Manual

ENGLISHen
12
Before disposal, discharge the battery pack in the
power tool. Prevent the contacts from short-
circuiting (e. g. by protecting them with adhesive
tape).
f
Explanatory notes on the specifications on page 3.
Changes due to technological progress reserved.
U=voltage of battery pack
n
0
=no-load speed
ΓΈ
max
= Maximum drill diameter
s
max
= Maximum impact rate
W=Single impact force
S = Single impact performance
m = Weight with smallest battery pack
D = Collar diameter
Measured values determined in conformity with
EN
60745.
Direct current
The technical specifications quoted are subject to
tolerances (in compliance with the relevant valid
standards).
Emission values
These values make it possible to assess the
emissions from the power tool and to compare
different power tools. Depending on the operating
conditions, the condition of the power tool or the
accessories, the actual load may be higher or lower.
For assessment purposes, please allow for breaks
and periods when the load is lower. Based on the
adjusted estimates, arrange protective measures
for the user e.g. organisational measures.
Vibration total value (vector sum of three directions)
determined in accordance with EN 60745:
a
h, HD
= Vibration emission value (hammer
drilling into concrete)
a
h, Cheq
= Vibration emission value (chiselling)
K
h,HD/Cheq
= Uncertainty (vibration)
Typical A-effective perceived sound levels:
L
pA
= Sound-pressure level
L
WA
= Acoustic power level
K
pA
, K
WA
= Uncertainty
During operation the noise level can exceed
80 dB(A).
Wear ear protectors!